Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › SFI SYSTEM
RM3250E _51 Engine / Hybrid System _037981 1GR-FE ENGINE CONTROL _0176666 SFI SYSTEM C

1GR-FE ENGINE CONTROL  SFI SYSTEM  P0660  Intake Manifold Tuning Valve Control Circuit / Open (Bank 1)  


DESCRIPTION

This circuit opens and closes the intake air control valve (intake air surge tank) in response to changes in the engine load in order to increase the intake efficiency using the Acoustic Control Induction System (ACIS).

When the engine speed is between 2200 and 4100 rpm and the throttle valve opening angle is 60° or more, the ECM supplies current to the actuator (on status) to close the intake air control valve. Under other conditions, the intake air control valve is open.

A115903E07
0.531,0.865 0.927,1.177 false 2.74,1.208 2.771,1.604 false 5.573,0.396 5.417,0.646 false 0.896,0.385 1.052,0.563 0.156,0.177 10 false 6 1.26,0.385 1.417,0.563 0.156,0.177 10 false 4 1.625,0.385 1.781,0.563 0.156,0.177 10 false 2 0.896,1.854 1.052,2.031 0.156,0.177 10 false 5 1.271,1.854 1.427,2.031 0.156,0.177 10 false 3 1.615,1.854 1.771,2.031 0.156,0.177 10 false 1 0.177,0.76 0.594,0.927 0.417,0.167 10 false IACV 2.469,1.615 3.406,1.781 0.938,0.167 10 false Throttle Valve 5.604,0.26 7.156,0.427 1.552,0.167 10 false Valve Closed (VSV: ON) 4.24,0.427 5.177,0.854 0.938,0.427 10 false Throttle Valve Opening Angle 5.594,2.333 6.917,2.573 1.323,0.24 10 false Engine Speed (rpm) 5.177,2.073 5.635,2.26 0.458,0.188 10 false 2200 4.906,1.094 5.167,1.365 0.26,0.271 10 false 60° 6.042,2.083 6.469,2.281 0.427,0.198 10 false 4100

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0660 Intake Manifold Tuning Valve Control Circuit / Open (Bank 1) The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
1.

The voltage of terminal ACIS of the ECM is low when the intake air control valve (for acoustic control induction system) is off (IACV open).

2.

The engine has been started.


·

Open or short in vacuum switching valve assembly (for ACIS) circuit

·

Vacuum switching valve assembly (for ACIS)

·

EFI-MAIN No. 1 relay

·

ECM


Comes on DTC stored

WIRING DIAGRAM

A348506E04
0.615,3.958 1.688,4.156 1.073,0.198 10 false Battery 0.479,3.313 1.552,3.51 1.073,0.198 10 false FL MAIN 3.0W 0.51,2.26 1.281,2.458 0.771,0.198 10 false J/B-B 0.333,1.594 0.646,1.792 0.313,0.198 10 false 2B 0.625,1.594 0.781,1.792 0.156,0.198 10 false 1 0.615,0.646 1.698,1.083 1.083,0.438 10 false EFI-MAIN NO. 1 1.729,1.271 3.875,1.469 2.146,0.198 10 false EFI-MAIN NO. 1 2.719,0.656 4.094,0.854 1.375,0.198 10 false EFI NO. 1 4.156,0.99 5.344,1.385 1.188,0.396 10 false Vacuum Switching Valve (for ACIS) 3.573,0.51 3.885,0.708 0.313,0.198 10 false 2N 3.625,0.323 3.927,0.521 0.302,0.198 10 false 1 1.365,1.594 1.677,1.792 0.313,0.198 10 false 2J 1.656,1.594 1.813,1.792 0.156,0.198 10 false 5 3.563,1.01 3.875,1.208 0.313,0.198 10 false 2P 3.615,0.823 3.771,1.021 0.156,0.198 10 false 9 4.156,0.823 4.615,1.021 0.458,0.198 10 false C6 2.188,1.813 3.833,2.802 1.646,0.99 10 false Instrument Panel Junction Block Assembly 4.073,0.396 4.229,0.594 0.156,0.198 10 false 1 5.208,0.385 5.365,0.583 0.156,0.198 10 false 2 5.365,0.51 5.823,0.708 0.458,0.198 10 false C12 5.438,0.302 5.75,0.5 0.313,0.198 10 false 5 5.708,0.385 6.167,0.583 0.458,0.198 10 false ACIS 5.698,1.875 6.313,2.073 0.615,0.198 10 false MREL 5.354,1.979 5.813,2.177 0.458,0.198 10 false G88 5.406,1.76 5.635,1.958 0.229,0.198 10 false 36 5.688,2.604 6,2.802 0.313,0.198 10 false E1 5.365,2.615 5.823,2.813 0.458,0.198 10 false C13 5.396,2.406 5.604,2.594 0.208,0.188 10 false 12 6.052,3.208 6.51,3.406 0.458,0.198 10 false ECM

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


HINT:

Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE VSV FOR INTAKE CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Intake Control.

Powertrain > Engine > Active Test
Tester Display
Activate the VSV for Intake Control
50004 234 3

e.

Check if operating noise can be heard when operating the intake air control valve using the GTS.

OK:

Operating noise can be heard.



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)
2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)
a.

Inspect the vacuum switching valve assembly (for ACIS).

Click hereEngine / Hybrid System>1GR-FE INTAKE / EXHAUST>VACUUM SWITCHING VALVE(for ACIS)>ON-VEHICLE INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))

NG

REPLACE VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)

3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))
A348213C01
0.417,1.083 0.833,1.417 0.417,0.333 0.104,0.083 0.417,0.281 0.313,0.198 10 false *a 0.5,1.167 0.958,1.365 0.458,0.198 10 false C6
*a Front view of wire harness connector
(to Vacuum Switching Valve Assembly (for ACIS))


a.

Disconnect the vacuum switching valve assembly (for ACIS) connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C6-1 - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) - ECM)

NG

5.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))
4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) - ECM)
a.

Disconnect the intake air control valve connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C6-2 - C12-5 (ACIS) Always Below 1 Ω
C6-2 or C12-5 (ACIS) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))
a.

Disconnect the instrument panel junction block assembly connector.


b.

Disconnect the intake air control valve connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2N-1 - C6-1 Always Below 1 Ω
2N-1 or C6-1 - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR