The thermistor assembly (ambient temperature sensor) is installed in front of the cooler condenser assembly to detect the ambient temperature which is used to control the air conditioning system AUTO mode. This sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly via the combination meter assembly. The resistance of the thermistor assembly (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. Conversely, as the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the thermistor assembly (ambient temperature sensor) and reads voltage changes due to changes in the resistance of the thermistor assembly (ambient temperature sensor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1412/12 | Ambient Temperature Sensor Circuit | ·
Diagnosis condition: None ·
Malfunction state: Open or short in thermistor assembly (ambient temperature sensor) circuit ·
Malfunction Period: None (as present malfunction), memorized (4 seconds or more) (as past malfunction) |
·
CAN communication system ·
Thermistor assembly (ambient temperature sensor) ·
Harness and connector ·
Air conditioning amplifier assembly ·
Combination meter assembly |
Memorized (4 seconds or more) | - |
The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the parentheses.
If the ambient temperature is approximately -52.9°C (-63.22°F) or less, DTC B1412/12 may be output even though the system is normal.
When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly (ambient temperature sensor) | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly (ambient temperature sensor) system malfunction:
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Tester Display |
|---|
| Ambient Temp Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Remove the thermistor assembly (ambient temperature sensor).
Inspect the thermistor assembly (ambient temperature sensor).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A43 thermistor assembly (ambient temperature sensor) connector.
Disconnect the G9 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A43-2 (+) - G9-33 (TX1+) | Always | Below 1 Ω |
| A43-1 (-) - G9-34 (TX1-) | Always | Below 1 Ω |
| A43-1 (-) - A43-2 (+) | Always | 10 kΩ or higher |
| A43-2 (+) or G9-33 (TX1+) - Body ground | Always | 10 kΩ or higher |
| A43-1 (-) or G9-34 (TX1-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the combination meter assembly.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER>REMOVAL
Since the combination meter assembly cannot be inspected while it is removed from the vehicle, replace the combination meter assembly with a normal one and check that the condition returns to normal.
Clear the DTC using the GTS or performing the panel diagnosis (sensor check).
Check for DTCs when the following conditions are met using the GTS or performing the panel diagnosis (sensor check).
DTC B1412/12 is not output.
| Proceed to |
|---|
| OK |
| NG |
OK
NG