| All functions of the air conditioning system do not operate.
|
IG power source circuit
|
|
| Back-up power source circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower operation. (blower motor does not operate)
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower control. (blower motor does not change speed)
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: Insufficient air flow.
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: Cooling effectiveness is poor.
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| No. 1 cooler expansion valve
|
|
| Compressor assembly with magnet clutch (for 1GR-FE)
|
|
| Compressor assembly with magnet clutch (for 1GD-FTV, 2GD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2KD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2TR-FE)
|
|
| Magnet clutch assembly (for 1GR-FE)
|
|
| Magnet clutch assembly (for 1GD-FTV, 2GD-FTV)
|
|
| Magnet clutch assembly (for 1KD-FTV)
|
|
| Magnet clutch assembly (for 2TR-FE)
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: No cool air comes out.
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| Air mix damper control servo motor circuit (front side air mix)
|
|
| Air conditioning compressor magnetic clutch circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| LIN communication circuit
|
|
| No. 1 cooler expansion valve
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| Air conditioning harness assembly
|
|
| Air conditioner pressure switch
|
|
| Compressor assembly with magnet clutch (for 1GR-FE)
|
|
| Compressor assembly with magnet clutch (for 1GD-FTV, 2GD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2KD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2TR-FE)
|
|
| Air conditioning amplifier assembly
|
|
| ECM (for 1GR-FE)
|
|
| ECM (for 1GD-FTV)
|
|
| ECM (for 2GD-FTV)
|
|
| ECM (for 2KD-FTV)
|
|
| ECM (for 2TR-FE)
|
|
| Temperature control: No warm air comes out.
|
Air mix damper control servo motor circuit (front side air mix)
|
|
| Evaporator temperature sensor circuit
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| LIN communication circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| Air conditioning harness assembly
|
|
| Heater radiator unit sub-assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM (for 1GR-FE)
|
|
| ECM (for 1GD-FTV)
|
|
| ECM (for 2GD-FTV)
|
|
| ECM (for 2KD-FTV)
|
|
| ECM (for 2TR-FE)
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow.*
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| Solar sensor circuit
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Air mix damper control servo motor circuit (front side air mix)
|
|
| Air inlet damper control servo motor circuit
|
|
| LIN communication circuit
|
|
| No. 1 cooler expansion valve
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| No. 1 blower damper servo sub-assembly
|
|
| Air conditioning harness assembly
|
|
| Heater radiator unit sub-assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM (for 1GR-FE)
|
|
| ECM (for 1GD-FTV)
|
|
| ECM (for 2GD-FTV)
|
|
| ECM (for 2KD-FTV)
|
|
| ECM (for 2TR-FE)
|
|
| Temperature control: No temperature control. (only Max. cool or Max. hot)
|
Air mix damper control servo motor circuit (front side air mix)
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Solar sensor circuit
|
|
| LIN communication circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air inlet control.
|
Air inlet damper control servo motor circuit
|
|
| LIN communication circuit
|
|
| No. 1 blower damper servo sub-assembly
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air flow mode control.
|
Air outlet damper control servo motor circuit
|
|
| Air outlet damper control servo motor circuit (w/ Rear Face Register)
|
|
| LIN communication circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
|
| No. 2 air conditioning radiator damper servo sub-assembly (w/ Rear Face Register)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| Engine coolant does not warm up quickly when engine is cold (PTC heater does not operate). (w/ PTC Heater)
|
CAN communication system (for LHD)
|
|
| CAN communication system (for RHD)
|
|
| Proceed to "PTC Heater Circuit"
|
|
| Viscous with magnet clutch heater assembly does not operate when heater switch assembly is pushed while engine is cold. (w/ Viscous Heater)
|
CAN communication system (for LHD)
|
|
| Proceed to "Viscous Heater with Magnet Clutch Circuit"
|
|
| Engine idle up does not occur when idle up switch is pushed while engine is cold. (w/ Idle Up Switch)
|
CAN communication system (for RHD)
|
|
| Proceed to "Idle Up Switch Circuit"
|
|
| ECO mode switch does not operate.
|
CAN communication system (for LHD)
|
|
| CAN communication system (for RHD)
|
|
| Meter/gauge system
|
|
| Air conditioning amplifier assembly
|
|
| Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when ignition switch is off.
|
Back-up power source circuit
|
|
| Air conditioning amplifier assembly
|
|