The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioner unit to detect the temperature of the air that has passed through the evaporator and is used to control the air conditioning. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1413/13 | Evaporator Temperature Sensor Circuit | Open or short in No. 1 cooler thermistor (evaporator temperature sensor) circuit | ·
No. 1 cooler thermistor (evaporator temperature sensor) ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Memorized (4 seconds or more) | - |
The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the parentheses.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor (evaporator temperature sensor) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Remove the No. 1 cooler thermistor (evaporator temperature sensor).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL
Inspect the No. 1 cooler thermistor (evaporator temperature sensor).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the G77 air conditioning amplifier assembly connector.
Disconnect the G25 No. 1 cooler thermistor (evaporator temperature sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G77-4 (TE) - G25-1 | Always | Below 1 Ω |
| G77-5 (SG-2) - G25-2 | Always | Below 1 Ω |
| G25-1 - G25-2 | Always | 10 kΩ or higher |
| G77-4 (TE) or G25-1 - Body ground | Always | 10 kΩ or higher |
| G77-5 (SG-2) or G25-2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG