Home › Engine / Hybrid System › 2GD-FTV EMISSION CONTROL › UREA PUMP › from 2016.03
RM3250E _51 Engine / Hybrid System _038008 2GD-FTV EMISSION CONTROL _0262570 UREA PUMP A

2GD-FTV EMISSION CONTROL  UREA PUMP  REMOVAL  


PROCEDURE

Hide 77801A 1.REMOVE UREA TANK SUB-ASSEMBLY

Hide 2.REMOVE UREA TANK HARNESS

a.
A379872

Detach the clamp and disconnect the connector from the No. 1 urea tube with heater.


b.
A379873

Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump.


Hide 3.REMOVE NO. 1 UREA TUBE WITH HEATER

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube connector before disconnection. Clean if necessary.


a.
A379891

Detach the 2 clamps and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.


b.

Remove the No. 1 urea tube with heater from the urea pump.

i.
A379875C01
0,0 0,0 false
V100135

Lift Up


Detach the lock claw by lifting up the cover.


ii.
A379876C01
0,0 0,0 false
V100135

Pinch
V100136

Pull


Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the No. 1 urea tube with heater.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.

·

Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77871A 4.REMOVE UREA PUMP

a.
A379877N01
2.031,0.76 2.427,0.354 2.427,0.354 2.615,0.354 true 0.906,2.729 1.135,2.729 true 2.646,0.26 3.031,0.438 0.385,0.177 10 false SST 1.177,2.635 1.563,2.813 0.385,0.177 10 false SST

Set SST on the urea pump gauge retainer.

SST
09808-14030  (09808-01030, 09808-01040)

HINT:
·

Attach the claws of SST securely with the urea pump gauge retainer holes to secure SST.

·

Install SST while pressing the claws of SST against the urea pump gauge retainer (towards the center of SST).




b.
A379878N01
0.646,0.76 1.01,0.333 1.01,0.333 1.188,0.333 true 1.229,0.24 1.594,0.406 0.365,0.167 10 false SST

Using SST, loosen the urea pump gauge retainer.

SST
09808-14030  (09808-01010)

NOTICE:

Remove any foreign matter around the urea pump before this operation.


HINT:

Fit the tips of SST onto the ribs of the urea pump gauge retainer.



c.

Remove the urea pump gauge retainer.


d.
A379879

Remove the urea pump from the urea tank sub-assembly.


e.
A379880

Remove the gasket from the urea tank sub-assembly.