AIR CONDITIONING AMPLIFIER ASSEMBLY
| *A | w/ Rear Face Resister | *B | w/o Rear Face Resister |
Disconnect the G33 air conditioning amplifier assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G33-1 (IG+) - Body ground | G - Body ground | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| G33-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 Ω |
| G33-21 (B) - Body ground | W - Body ground | Power source (Back-up) | Always | 11 to 14 V |
Reconnect the G33 air conditioning amplifier assembly connector.
Measure the resistance, voltage and check for waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G33-3 (PTC3) - Body ground*1 | SB - Body ground | Quick heater assembly operation signal | ·
Engine starts ·
ECO mode switch: Off ·
Temperature settings: MAX HOT ·
Ambient temperature: 10°C (50°F) or lower ·
Engine coolant temperature: 64°C (147°F) or lower ·
Light control switch: Off ·
Blower switch: Off → on (after 30 seconds) |
11 to 14 V → Below 1 V |
| G33-4 (SWVC) - Body ground*2, *3 | R - Body ground | ·
Heater switch assembly operation signal*2 ·
Idle up switch operation signal*3 |
·
Engine running ·
"A/C" switch: On ·
Blower switch: On (LO level) ·
Heater switch assembly: Off → on*2 ·
Idle up switch: Off → on*3 |
Below 1 V → 11 to 14 V |
| G33-9 (PSW) - Body ground | L - Body ground | Air conditioner pressure switch signal | ·
Engine running ·
Refrigerant pressure normal ·
Blower switch: On (LO level) ·
"A/C" switch: On |
Below 1 V |
·
Engine running ·
Refrigerant pressure less than 0.196 MPa (2.0 kgf/cm2, 28 psi) or more than 3.14 MPa (32.0 kgf/cm2, 455 psi) ·
Blower switch: On (LO level) ·
"A/C" switch: On |
11 to 14 V | |||
| G33-11 (TX+) | GR | CAN communication line | - | - |
| G33-12 (TX-) | W | CAN communication line | - | - |
| G33-17 (AC1) - Body ground | GR - Body ground | Idle-up request signal | ·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: Off |
11 to 14 V |
·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: On |
Below 1 V | |||
| G33-19 (MG+) - Body ground*2 | P - Body ground | Viscous with magnetic clutch heater assembly operation signal | ·
Engine running ·
Blower switch: On (LO level) ·
Heater switch assembly: Off or on (magnet clutch off) |
11 to 14 V |
·
Engine running ·
Blower switch: On (LO level) ·
Heater switch assembly: On (magnet clutch on) |
Below 1 V | |||
| G33-20 (MGC) - Body ground | V - Body ground | Magnet clutch drive output signal | ·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: Off or on (magnet clutch off) |
11 to 14 V |
·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: On (magnet clutch on) |
Below 1 V | |||
| G33-22 (BLW) - Body ground | P - Body ground | Blower motor speed control signal | ·
Ignition switch ON ·
Blower switch: On (LO level) |
Pulse generation
(See Waveform 1) |
| G33-24 (ACT) - Body ground | LG - Body ground | Magnet clutch on permit input signal | ·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: Off or on (magnet clutch off) |
Below 1 V |
·
Engine running ·
Blower switch: On (LO level) ·
"A/C" switch: On (magnet clutch on) |
4.5 to 5.5 V | |||
| G33-29 (TR) - G33-34 (SG-2) | V - L | Room temperature sensor signal | ·
Ignition switch ON ·
Cabin temperature: 25°C (77°F) |
1.8 to 2.2 V |
·
Ignition switch ON ·
Cabin temperature: 40°C (104°F) |
1.2 to 1.6 V | |||
| G33-30 (S5-3) - Body ground | G - Body ground | Power supply for solar sensor | Ignition switch ON | 4.5 to 5.5 V |
| G33-33 (TSD) - Body ground | P - Body ground | Solar sensor signal | ·
Ignition switch ON ·
Solar sensor subjected to electric light |
0.8 to 4.3 V |
·
Ignition switch ON ·
Solar sensor covered with cloth |
Below 0.8 V | |||
| G33-34 (SG-2) - Body ground | L - Body ground | Ground for room temperature sensor | Always | Below 1 Ω |
| G33-37 (LIN1) - Body ground | R - Body ground | LIN communication signal | Ignition switch ON | Pulse generation |
| G33-39 (PTC1) - Body ground*1 | L - Body ground | Quick heater assembly operation signal | ·
Engine starts ·
ECO mode switch: Off ·
Temperature settings: MAX HOT ·
Ambient temperature: 10°C (50°F) or lower ·
Engine coolant temperature: 64°C (147°F) or lower ·
Light control switch: Off ·
Blower switch: Off → on (after 10 seconds) |
11 to 14 V → Below 1 V |
| G33-40 (PTC2) - Body ground*1 | W - Body ground | Quick heater assembly operation signal | ·
Engine starts ·
ECO mode switch: Off ·
Temperature settings: MAX HOT ·
Ambient temperature: 10°C (50°F) or lower ·
Engine coolant temperature: 64°C (147°F) or lower ·
Light control switch: Off ·
Blower switch: Off → on (after 20 seconds) |
11 to 14 V → Below 1 V |
| z5-3 (BUS) - z5-2 (BUSG)*4
z6-3 (BUS) - z6-2 (BUSG)*5 |
- | BUS IC control signal | Ignition switch ON | Pulse generation
(See Waveform 2) |
| z5-2 (BUSG) - Body ground*4
z6-2 (BUSG) - Body ground*5 |
- | Ground for BUS IC | Always | Below 1 Ω |
| z5-4 (BBUS) - z5-2 (BUSG)*4
z6-4 (BBUS) - z6-2 (BUSG)*5 |
- | Power supply for BUS IC | Always | 11 to 14 V |
| z5-5 (SG-4) - Body ground*4
z6-5 (SG-4) - Body ground*5 |
- | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| z5-6 (TE) - z5-5 (SG-4)*4
z6-6 (TE) - z6-5 (SG-4)*5 |
- | Evaporator temperature sensor signal | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
*1: w/ PTC Heater
*2: w/ Viscous Heater
*3: w/ Idle Up Switch
*4: w/ Rear Face Resister
*5: w/o Rear Face Resister
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | G33-22 (BLW) - Body ground |
| Tool Setting | 2 V/DIV., 500 μs/DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
Blower switch: On (LO level) |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | z5-3 (BUS) - z5-2 (BUSG)*1
z6-3 (BUS) - z6-2 (BUSG)*2 |
| Tool Setting | 2 V/DIV., 2 ms/DIV. |
| Vehicle Condition | Ignition switch ON |
*1: w/ Rear Face Resister
*2: w/o Rear Face Resister
AIR CONDITIONING CONTROL ASSEMBLY
Disconnect the G32 air conditioning control assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G32-2 (IG) - Body ground | L - Body ground | Power source (IG) | Ignition switch ON | 11 to 14 V*1
10.5 to 16 V*2 |
| Ignition switch off | Below 1 V | |||
| G32-4 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 Ω |
*1: w/o Stop and Start System
*2: w/ Stop and Start System
Reconnect the G32 air conditioning control assembly connector.
Measure the waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G32-3 (LIN1) - Body ground | R - Body ground | LIN communication signal | Ignition switch ON | Pulse generation |
ECM
for 1GD-FTV (w/ DPF):Engine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(w/ DPF)>TERMINALS OF ECM
for 2GD-FTV (w/ DPF):Engine / Hybrid System>2GD-FTV ENGINE CONTROL>ECD SYSTEM>TERMINALS OF ECM