Home › Engine / Hybrid System › 2TR-FE EMISSION CONTROL › AIR SWITCHING VALVE(w/ Secondary Air Injection System)
RM33J0E _51 Engine / Hybrid System _038457 2TR-FE EMISSION CONTROL _0189936 AIR SWITCHING VALVE(w/ Secondary Air Injection System) A

2TR-FE EMISSION CONTROL  AIR SWITCHING VALVE(w/ Secondary Air Injection System)  INSTALLATION  


PROCEDURE

Hide 25710 1.INSTALL AIR SWITCHING VALVE ASSEMBLY

a.

Set the No. 1 exhaust manifold heat insulator in place.


b.

Install the air switching valve assembly with 2 new nuts.

Torque:
26 N*m (265 kgf*cm, 19 ft.*lbf)


c.

Connect the air switching valve connector.


d.

Connect the vacuum hose.


Hide 17117B 2.INSTALL NO. 4 INTAKE PIPE

a.
A346855N01
2.208,0.479 2.344,0.667 0.135,0.188 10 true 1 1.604,1.781 1.74,1.969 0.135,0.188 10 true 2 1.156,0.375 1.292,0.563 0.135,0.188 10 true 3 0.771,1.677 0.906,1.865 0.135,0.188 10 true 4

Install 2 new gaskets and the No. 4 intake pipe with 4 new nuts and tighten the nuts in the order shown in the illustration. Then, tighten the nuts labeled 1 and 3 to the torque specification again.

Torque:
26 N*m (265 kgf*cm, 19 ft.*lbf)


b.

Check that the nuts are tightened to the torque specification.


Hide 17167 3.INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR

a.

Install the No. 1 exhaust manifold heat insulator with the 5 bolts.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


Hide 17344 4.CONNECT NO. 4 AIR INJECTION SYSTEM HOSE

a.
A346858C01
0.99,0.698 0.99,0.219 0.99,0.219 1.427,0.219 true 1.417,1.167 1.073,1.167 1.073,1.167 1.073,0.719 true 1.219,1.156 1.219,0.719 true 1.448,0.104 1.656,0.302 0.208,0.198 10 false *a 1.438,1.063 1.625,1.26 0.188,0.198 10 false *b 2.469,0.094 2.656,0.292 0.188,0.198 10 true *c 2,0.823 2.198,1.01 0.198,0.188 10 false *d 2.688,0.135 2.979,0.323 0.292,0.188 10 false 90°
*a Rib
*b Paint Mark
*c Upper
*d RH Side


Connect the No. 4 air injection system hose so that its paint mark aligns with the rib of the air switching valve assembly as shown in the illustration.

HINT:
·

Make sure the paint mark of the No. 4 air injection system hose is facing upward.

·

Make sure the direction of the hose clamp is as shown in the illustration.




b.

Slide the clip to secure the No. 4 air injection system hose.


Hide 17701 5.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

Hide 17801 6.INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 17705 7.INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH NO. 1 AIR CLEANER HOSE