When the theft deterrent system is switched from the armed state to the alarm sounding state, the body ECU transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
Inspect the fuses for circuits related to this system before performing the following procedure.
w/ Door Control Battery:
As the door control battery is installed between the vehicle battery and body ECU, first perform the inspections to confirm that there are no malfunctions in the power source circuit for the body ECU before performing this troubleshooting procedure.
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>PRECAUTION
w/ Automatic Light Control System:
If the body ECU has been replaced, it is necessary to initialize the body ECU.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Remove the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>REMOVAL
Inspect the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Horn Relay (S-HORN) |
Remove the horn relay (S-HORN).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the body ECU.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Disconnect the instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2P-14 - A-10 (SH) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG (for LHD) |
| NG (for RHD) |
OK
NG (for LHD)
NG (for RHD)
Remove the horn relay (S-HORN).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 1 - Body ground | Always | 11 to 14 V |
| Relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the horn relay (S-HORN).
Disconnect the A42 security horn assembly connector.
Disconnect the 2P instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - A42-1 | Always | Below 1 Ω |
| Relay terminal 2 - 2P-14 | Always | Below 1 Ω |
| Relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| A42-1 - Body ground | Always | 10 kΩ or higher |
| 2P-14 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK (for LHD) |
| OK (for RHD) |
| NG |
OK (for LHD)
OK (for RHD)
NG