Home › Power Source / Network › 2TR-FE BATTERY / CHARGING › GENERATOR(for 90A Type) › from 2015.11
RM33J0E _57 Power Source / Network _038487 2TR-FE BATTERY / CHARGING _0233419 GENERATOR(for 90A Type) A

2TR-FE BATTERY / CHARGING  GENERATOR(for 90A Type)  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 17705 3.REMOVE AIR CLEANER CAP SUB-ASSEMBLY WITH NO. 1 AIR CLEANER HOSE

Hide 17801 4.REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 17701 5.REMOVE AIR CLEANER CASE SUB-ASSEMBLY

Hide 16361A 6.REMOVE FAN AND GENERATOR V BELT

Hide 27020 7.REMOVE GENERATOR ASSEMBLY

A345753

a.

Disconnect the generator connector.


b.

Remove the terminal cap.


c.

Remove the bolt and generator bracket.


d.

Remove the nut and disconnect the wire harness from terminal B.


e.

Remove the 2 bolts and generator assembly.