Refer to the system description for DTC P2757.
Click hereDrivetrain>AC60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>P2757
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2759 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic). | ·
Open or short in shift solenoid valve SLU circuit ·
Shift solenoid valve SLU ·
ECM |
Comes on | DTC stored |
When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will illuminate the MIL and store this DTC.
Perform registration and/or initialization when parts related to the automatic transmission are replaced.
Click hereDrivetrain>AC60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>INITIALIZATION
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform the Lock-up Function in Road Test.
Click hereDrivetrain>AC60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>ROAD TEST
Check for DTCs again.
Click hereDrivetrain>AC60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 21 (SLU+) - 22 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 21 (SLU+) - Body ground | Always | 10 kΩ or higher |
| 22 (SLU-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C54-2 (SLU+) - C54-1 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| C54-2 (SLU+) - Body ground | Always | 10 kΩ or higher |
| C54-1 (SLU-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SLU |
Remove shift solenoid valve SLU.
Click hereDrivetrain>AC60E AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG