When the theft deterrent system is switched from the armed state to the alarm sounding state, the body ECU transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
Inspect the fuses for circuits related to this system before performing the following procedure.
If the body ECU has been replaced, it is necessary to initialize the body ECU.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Remove the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>REMOVAL
Inspect the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Horn Relay (S-HORN) |
Remove the horn relay (S-HORN).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the body ECU.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Disconnect the instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2P-14 - A-10 (SH) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the horn relay (S-HORN).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 1 - Body ground | Always | 11 to 14 V |
| Relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the horn relay (S-HORN).
Disconnect the A31 security horn assembly connector.
Disconnect the 2P instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - A31-1 | Always | Below 1 Ω |
| Relay terminal 2 - 2P-14 | Always | Below 1 Ω |
| Relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| A31-1 - Body ground | Always | 10 kΩ or higher |
| 2P-14 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG