This circuit provides power to operate the body ECU.
Inspect the fuses for circuits related to this system before performing the following procedure.
If the body ECU has been replaced, it is necessary to initialize the body ECU.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
Disconnect the instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2J-5 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-5 - Body ground | Ignition switch ON | 11 to 14 V |
| 2J-3 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the body ECU.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2J-5 - A-1 (GND) | Always | Below 1 Ω |
| 2D-5 - A-7 (IG) | Always | Below 1 Ω |
| 2J-3 - A-6 (BECU) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>THEFT DETERRENT SYSTEM>PROBLEM SYMPTOMS TABLE
NG