Home › Power Source / Network › 2GD-FTV BATTERY / CHARGING › GENERATOR › from 2016.01
RM3270E _57 Power Source / Network _048964 2GD-FTV BATTERY / CHARGING _0239209 GENERATOR A

2GD-FTV BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 74404B 3.REMOVE BATTERY CLAMP SUB-ASSEMBLY

a.
A347637

Loosen the 2 nuts.


b.

Remove the 2 battery clamp bolts and battery clamp sub-assembly.


Hide 28800 4.REMOVE BATTERY

Hide 74431 5.REMOVE BATTERY TRAY

Hide 17344E 6.REMOVE NO. 4 AIR HOSE

Hide 16361A 7.REMOVE FAN AND GENERATOR V BELT

Hide 27020 8.REMOVE GENERATOR ASSEMBLY

a.
A355306

Disconnect the intake air temperature sensor connector.


b.

Disconnect the generator connector and detach the clamp.


c.

Remove the terminal cap.


d.

Remove the nut and disconnect the wire harness from terminal B.


e.
A349099

Detach the 3 clamps and disconnect the wire harness.


f.
A355307

Remove the 2 bolts and generator assembly.


g.
A347640

Remove the 2 bolts and 2 generator brackets.