Home › Engine / Hybrid System › 1GR-FE COOLING › THERMOSTAT › from 2016.01
RM3270E _51 Engine / Hybrid System _048951 1GR-FE COOLING _0241387 THERMOSTAT A

1GR-FE COOLING  THERMOSTAT  INSTALLATION  


PROCEDURE

Hide 16031 1.INSTALL WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

a.

Install a new gasket to the water inlet sub-assembly with thermostat.


b.

Install the water inlet sub-assembly with thermostat to the water inlet assembly with the 3 nuts.

Torque:
9.0 N*m (92 kgf*cm, 80 in.*lbf)


Hide 16572 2.CONNECT RADIATOR HOSE OUTLET

a.

Connect the radiator hose outlet to the water inlet sub-assembly with thermostat, and slide the hose clamp to secure the hose.

NOTICE:

Connect the radiator hose outlet so that the paint mark on the radiator hose outlet is aligned with the protrusions of the water inlet sub-assembly with thermostat.

Click hereEngine / Hybrid System>1GR-FE COOLING>RADIATOR>INSTALLATION



Hide 51410 5.INSTALL NO. 1 ENGINE UNDER COVER ASSEMBLY