The cooler thermistor is installed in the instrument panel to detect the room temperature and control the heater and air conditioning AUTO function. The resistance of the cooler thermistor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler thermistor and reads voltage changes as the resistance of the cooler thermistor changes.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| 11 | Room Temperature Sensor Circuit | An open or short in the room temperature sensor circuit. | ·
Cooler thermistor ·
Air conditioning amplifier assembly ·
Harness or connector |
Memorized
(8.5 min. or more) |
If the room temperature is approximately - 18.6°C (1.48°F) or lower, DTC 11 may be output even though the system is normal. |
Memory: The air conditioning amplifier stores the DTC of the respective malfunction that has been detected for the period of time indicated in parentheses.
Remove the cooler thermistor.
| *a | Resistance (kΩ) |
| *b | Temperature |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.
When measuring the resistance, the cooler thermistor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (Refer to the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the air conditioning amplifier assembly with its connectors still connected.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G95-18 (TR) - G95-13 (SG-3) | ·
Ignition switch ON ·
Cabin temperature 25°C (77°F) |
1.8 to 2.2 V |
·
Ignition switch ON ·
Cabin temperature 40°C (104°F) |
1.2 to 1.6 V |
As the temperature increases, the voltage decreases.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table.) | A |
| OK (When troubleshooting according to DTC.) | B |
| NG | C |
A
B
C
Disconnect the G110 cooler thermistor connector.
Disconnect the G95 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G95-18 (TR) - G110-2 | Always | Below 1 Ω |
| G95-13 (SG-3) - G110-1 | ||
| G95-18 (TR) - Body ground | Always | 10 kΩ or higher |
| G95-13 (SG-3) - Body ground |
| Proceed to |
|---|
| OK |
| NG |
OK
NG