HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  12  Ambient Temperature Sensor Circuit  


DESCRIPTION

The thermistor assembly connected to the accessory meter detects fluctuations in the ambient temperature. This information is used for controlling the interior temperature. The accessory meter assembly detects the resistance of the thermistor assembly and sends this information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note
12 Ambient Temperature Sensor Circuit An open or short in ambient temperature sensor circuit
·

Thermistor assembly

·

Accessory meter assembly

·

Air conditioning amplifier assembly

·

Harness or connector


- -

HINT:

Memory: The air conditioning amplifier stores the DTC of the respective malfunction that has been detected for the period of time indicated in parentheses.


WIRING DIAGRAM

E227734
5.823,0.823 6.375,1.188 0.552,0.365 10 TAMO 3.708,1.833 5.146,2.229 1.438,0.396 10 Thermistor Assembly 0.156,2.865 1.854,3.281 1.698,0.417 10 Accessory Meter Assembly 0.76,0.823 1.26,1.177 0.5,0.354 10 DATA 0.823,1.313 1.25,1.635 0.427,0.323 10 TH+ 0.885,2.313 1.271,2.625 0.385,0.313 10 SG 3.719,1.677 4.156,1.948 0.438,0.271 10 A22 5.5,2.729 5.917,3.073 0.417,0.344 10 G94 5.521,0.719 5.833,1.01 0.313,0.292 10 18 1.25,0.74 1.479,1 0.229,0.26 10 9 1.25,1.219 1.49,1.51 0.24,0.292 10 3 0.156,2.719 0.573,2.979 0.417,0.26 10 G112 1.25,2.219 1.5,2.51 0.25,0.292 10 2 3.396,1.51 3.677,1.792 0.281,0.281 10 2 3.417,2.146 3.688,2.458 0.271,0.313 10 1 5.5,2.927 7.135,3.74 1.635,0.813 10 Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

NOTICE:

Check that the accessory meter assembly illuminates normally before performing the following procedure.


PROCEDURE

1.CHECK ACCESSORY METER ASSEMBLY
a.

Check the difference between the ambient temperature value displayed on the accessory meter assembly and the actual ambient temperature.

OK:

The ambient temperature displayed on the accessory meter assembly and the actual ambient temperature are almost the same.


HINT:

The temperature displayed on the accessory meter assembly and the actual temperature detected by the thermistor assembly may differ when the ambient temperature changes significantly (for example, when the vehicle is entering/exiting tunnels, or the vehicle speed or wind direction changes).



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (ACCESSORY METER - AIR CONDITIONING AMPLIFIER)

NG

3.INSPECT THERMISTOR ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (ACCESSORY METER - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the G112 accessory meter assembly connector.


b.

Disconnect the G94 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G112-9 (DATA) - G94-18 (TAMO) Always Below 1 Ω
G112-9 (DATA) - Body ground Always 10 kΩ or higher



Result:
Result Proceed to
OK (When troubleshooting according to problem symptoms table.) A
OK (When troubleshooting according to DTC.) B
NG C



A

B

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT THERMISTOR ASSEMBLY

b.
E271488
0.115,1.667 0.469,1.99 0.354,0.323 10 *a 1.552,4.385 1.875,4.656 0.323,0.271 10 *b
*a Resistance (kΩ)
*b Temperature


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the thermistor assembly may change the resistance value. Be sure to hold the connector of the thermistor assembly.

·

When measuring the resistance, the thermistor assembly temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (Refer to the graph).



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (THERMISTOR - ACCESSORY METER)

NG

4.CHECK HARNESS AND CONNECTOR (THERMISTOR - ACCESSORY METER)
a.

Disconnect the A22 thermistor assembly connector.


b.

Disconnect the G112 accessory meter assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G112-3 (TH+) - A22-2 Always Below 1 Ω
G112-2 (SG) - A22-1
G112-3 (TH+) - Body ground Always 10 kΩ or higher
G112-2 (SG) - Body ground



Result:
Proceed to
OK
NG



OK

REPLACE ACCESSORY METER ASSEMBLY

NG