Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM1880E _58 Vehicle Interior _013245 HEATING / AIR CONDITIONING _0068660 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  13  Evaporator Temperature Sensor Circuit  


DESCRIPTION

The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator which is then used in air conditioning control. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This thermistor is used for frost prevention.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note
13 Evaporator Temperature Sensor Circuit An open or short in evaporator temperature sensor circuit
·

No. 1 cooler thermistor

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(8.5 min. or more)
-

HINT:

Memory: The air conditioning amplifier stores the DTC of the respective malfunction that has been detected for the period of time indicated in parentheses.


WIRING DIAGRAM

E227735
5.25,2.688 5.708,3.042 0.458,0.354 10 G95 2.427,1.24 2.729,1.542 0.302,0.302 10 1 2.427,1.813 2.698,2.094 0.271,0.281 10 2 5.25,2.865 6.917,3.635 1.667,0.771 10 Air Conditioning Amplifier Assembly 5.521,0.781 5.885,1.104 0.365,0.323 10 TE 1.333,1.354 1.813,1.75 0.479,0.396 10 G30 5.292,2.115 5.625,2.427 0.333,0.313 10 14 5.354,0.646 5.646,0.938 0.292,0.292 10 1 5.51,2.229 6.021,2.573 0.51,0.344 10 SG-4 1.354,1.51 2.167,2.26 0.813,0.75 10 No. 1 Cooler Thermistor

PROCEDURE

1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
a.

Remove the air conditioning amplifier assembly with its connectors still connected.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER(for Automatic Air Conditioning System)>REMOVAL


b.
E225456
2.167,0.135 2.583,0.385 0.417,0.25 1.719,1.667 2.125,1.01 true 2.833,0.719 3,0.385 true 0.125,0.083 0.438,0.396 0.313,0.313 10 false *a 2.25,0.188 2.646,0.521 0.396,0.333 10 false G95 1.5,1.688 2.063,2.052 0.563,0.365 10 false SG-4 3.01,0.229 3.396,0.531 0.385,0.302 10 false TE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G95-1 (TE) - G95-14 (SG-4)
·

Ignition switch ON

·

Evaporator temperature 0°C (32°F)


2.0 to 2.4 V
·

Ignition switch ON

·

Evaporator temperature 15°C (59°F)


1.4 to 1.8 V


HINT:

As the temperature increases, the voltage decreases.


Result:
Result Proceed to
OK (When troubleshooting according to problem symptoms table.) A
OK (When troubleshooting according to DTC.) B
NG C




A

B

C

2.INSPECT NO. 1 COOLER THERMISTOR
2.INSPECT NO. 1 COOLER THERMISTOR

b.
E272042
0.385,1.948 0.677,2.26 0.292,0.313 10 false *a 1.771,4.156 2.063,4.469 0.292,0.313 10 false *b
*a Resistance (kΩ)
*b Temperature


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
-5°C (23°F) 5.65 to 6.95 kΩ
0°C (32°F) 4.40 to 5.35 kΩ
5°C (41°F) 3.40 to 4.15 kΩ
10°C (50°F) 2.70 to 3.25 kΩ
15°C (59°F) 2.14 to 2.58 kΩ
20°C (68°F) 1.71 to 2.05 kΩ
25°C (77°F) 1.38 to 1.64 kΩ
30°C (86°F) 1.11 to 1.32 kΩ


NOTICE:
·

Even slightly touching the No. 1 cooler thermistor may change the resistance value. Be sure to hold the connector of the No. 1 cooler thermistor.

·

When measuring the resistance, the No. 1 cooler thermistor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (Refer to the graph).



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)

NG

3.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the G30 No. 1 cooler thermistor connector.


b.

Disconnect the G95 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G95-1 (TE) - G30-1 Always Below 1 Ω
G95-14 (SG-4) - G30-2
G95-1 (TE) - Body ground Always 10 kΩ or higher
G95-14 (SG-4) - Body ground



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR