The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator which is then used in air conditioning control. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This thermistor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| 13 | Evaporator Temperature Sensor Circuit | An open or short in evaporator temperature sensor circuit | ·
No. 1 cooler thermistor ·
Air conditioning amplifier assembly ·
Harness or connector |
Memorized
(8.5 min. or more) |
- |
Memory: The air conditioning amplifier stores the DTC of the respective malfunction that has been detected for the period of time indicated in parentheses.
Remove the air conditioning amplifier assembly with its connectors still connected.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G95-1 (TE) - G95-14 (SG-4) | ·
Ignition switch ON ·
Evaporator temperature 0°C (32°F) |
2.0 to 2.4 V |
·
Ignition switch ON ·
Evaporator temperature 15°C (59°F) |
1.4 to 1.8 V |
As the temperature increases, the voltage decreases.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table.) | A |
| OK (When troubleshooting according to DTC.) | B |
| NG | C |
A
B
C
Remove the No. 1 cooler thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL
| *a | Resistance (kΩ) |
| *b | Temperature |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
Even slightly touching the No. 1 cooler thermistor may change the resistance value. Be sure to hold the connector of the No. 1 cooler thermistor.
When measuring the resistance, the No. 1 cooler thermistor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (Refer to the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G30 No. 1 cooler thermistor connector.
Disconnect the G95 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G95-1 (TE) - G30-1 | Always | Below 1 Ω |
| G95-14 (SG-4) - G30-2 | ||
| G95-1 (TE) - Body ground | Always | 10 kΩ or higher |
| G95-14 (SG-4) - Body ground |
| Proceed to |
|---|
| OK |
| NG |
OK