B278A Short to GND in Immobiliser System Power Source Circuit
Diagnostic trouble codes · Vehicles built from Aug 2013
DESCRIPTION
This DTC is stored when the engine switch power source supply line is open or shorted.| DTC Code |
DTC Detection Condition |
Trouble Area |
| B278A |
The engine switch power source supply line is open or shorted. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Before replacing the certification ECU, refer to the Service Bulletin.
| 1. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ENGINE SWITCH) |
Disconnect the G38 ECU connector.
Disconnect the G36 switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
G38-28 (VC5) - G36-14 (VC5)
Always
Below 1 Ω
G38-36 (AGND) - G36-8 (AGND)
G38-28 (VC5) or G36-14 (VC5) - Body ground
Always
10 kΩ or higher
G38-36 (AGND) or G36-8 (AGND) - Body ground
|
|
||||
| OK | |
| 2. CHECK CERTIFICATION ECU |
Using an oscilloscope, check the waveform.

Measurement Condition Item
Content
Tester Connection
G36-14 (VC5) - G36-8 (AGND)
Tool Setting
2 V/DIV., 20 ms./DIV.
Condition
Engine switch off, key not in cabin, and 30 seconds or less after engine switch pushed
- OK:
- Waveform is output normally (refer to illustration).
Text in Illustration *a
Component with harness connected
(Engine Switch)
- HINT:
- If replacing the Engine Switch, refer to the procedures below.
- for 1GR-FE (for LHDClick here)
- for 1GR-FE (for RHDClick here
- for 2TR-FEClick here)
- for 1KD-FTV (for LHDClick here)
- for 1KD-FTV (for RHDClick here)
- for 1GR-FE (for LHDClick here)
|
|
||||
| OK | ||
| ||