2013-2015 Land Cruiser Prado · Service Manual Drivetrain

P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

Refer to DTC P2714 (Click here).
DTC Code
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

C214969E01

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)

  1. C214964E04
    Disconnect the C58 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    2 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C214336E06
    Disconnect the C62 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C62-23 (SLT+) - C62-24 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C62-23 (SLT+) - Body ground
    Always
    10 kΩ or higher
    C62-24 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SLT

  1. C209928E03
    Remove shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SLT)


NG
REPLACE SHIFT SOLENOID VALVE SLT (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P2714 Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT) (from Aug 2014)P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (from Aug 2014) →