P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
Refer to DTC P2714 (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1-trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the C30 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
14 (SLT+) - 6 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
14 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
6 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
Text in Illustration *a
Component without harness connected
(Transmission Wire)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the G69 TCM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
G69-20 (SLT+) - G69-19 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
G69-20 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
G69-19 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to TCM)
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
Remove shift solenoid valve SLT.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 2
| *a |
Component without harness connected (Shift Solenoid Valve SLT) |
|
|
||||
| OK | ||
| ||