INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
- HINT:
- As the temperature increases, the resistance decreases (refer to the graph).
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
Text in Illustration *a
Component without harness connected
(Cooler thermistor (Room Temperature Sensor))
*b
Resistance kΩ
*c
Temperature °C (°F)