Starter Signal Circuit
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
When the engine is cranked, the intake air flow becomes slow so fuel vaporization is poor. A rich mixture is therefore necessary in order to achieve good startability. While the engine is being cranked, the battery voltage is applied to terminal STA of the ECM. The starter signal is mainly used to increase the fuel injection volume for starting and after-start injection control.WIRING DIAGRAM


INSPECTION PROCEDURE
When using intelligent tester:
| 1. READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Read the STA signal on the intelligent tester while the starter operates.
- OK:
Ignition Switch Position
Starter SIG
LOCK, ACC, ON
OFF
START
ON
|
|
||||
| OK | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM) |
Disconnect the clutch start switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
for LHD Tester Connection
Condition
Specified Condition
A40-1 - G61-11 (STA)
Always
Below 1 Ω
for RHD Tester Connection
Condition
Specified Condition
r1-1 - G61-11 (STA)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
for LHD Tester Connection
Condition
Specified Condition
A40-1 or G61-11 (STA) - Body ground
Always
10 kΩ higher
for RHD Tester Connection
Condition
Specified Condition
r1-1 or G61-11 (STA) - Body ground
Always
10 kΩ higher
Reconnect the clutch start switch connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||