INSTALLATION
Removal / installation · Vehicles built from Aug 2013
| 1. INSTALL AIR SWITCHING VALVE ASSEMBLY |
Set the No. 1 exhaust manifold heat insulator in place.
Install the air switching valve with 2 new nuts.
- Torque:
- 20 N*m{ 204 kgf*cm , 15 ft.*lbf }
Connect the connector.
w/ Manifold Absolute Pressure Sensor:
Connect the vacuum hose.
| 2. INSTALL NO. 4 INTAKE PIPE |
Install 2 new gaskets and the No. 4 intake pipe with 4 new nuts in the order shown in the illustration. Tighten the nuts labeled 1 and 3 to the torque specification again.

- Torque:
- 20 N*m{ 204 kgf*cm , 15 ft.*lbf }
Check that the nuts are tightened to the torque specification.
| 3. INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR |
Install the No. 1 exhaust manifold heat insulator with the 5 bolts.
- Torque:
- 12 N*m{ 122 kgf*cm , 9 ft.*lbf }
| 4. CONNECT NO. 1 AIR INJECTION SYSTEM HOSE |
Connect the No. 1 air injection system hose so that its paint mark aligns with the rib of the air switching valve as shown in the illustration.

Text in Illustration *1
Rib
*2
Paint Mark
*a
Upper
*b
RH Side
- HINT:
- Make sure the paint mark of the No. 1 air injection system hose is facing upward.
- Make sure the direction of the hose clamp is as shown in the illustration.
- Make sure the paint mark of the No. 1 air injection system hose is facing upward.
| 5. INSTALL FRONT NO. 1 FENDER APRON TO FRAME SEAL RH |
Install the front No. 1 fender apron to frame seal with the 5 clips.
| 6. INSTALL AIR CLEANER CASE |
Install the air cleaner case with the 3 bolts.
- Torque:
- 12 N*m{ 122 kgf*cm , 9 ft.*lbf }
Install the air cleaner filter element.
| 7. INSTALL AIR CLEANER AND HOSE |
Install the air cleaner hose, align its matchmark with the matchmark of the air cleaner cap as shown in the illustration.

Text in Illustration *1
Matchmark
*a
Upper Side
*b
Front
Tighten the hose clamp.
- Torque:
- 5.0 N*m{ 51 kgf*cm , 44 in.*lbf }
Attach the 4 clamps.
Install the ground wire and clamp with the bolt.
- Torque:
- 8.5 N*m{ 87 kgf*cm , 75 in.*lbf }
Connect the mass air flow meter connector and attach the 3 clamps.