ECM Communication Stop Mode
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| ECM Communication Stop Mode |
Either condition is met:
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND) |
for 1GR-FE:
Connect the cable to the negative (-) battery terminal.


Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Disconnect the C36, C37 and G55 ECM connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C36-12 (E1) - Body ground
Always
Below 1 Ω
C37-14 (E01) - Body ground
Always
Below 1 Ω
C37-15 (E02) - Body ground
Always
Below 1 Ω
C37-10 (ME01) - Body ground
Always
Below 1 Ω
G55-12 (EC) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G55-24 (BATT) - Body ground
Always
11 to 14 V
G55-23 (+B2) - Body ground
Battery positive (+) voltage applied to terminal G55-9 (MREL)
11 to 14 V
G55-22 (+B) - Body ground
Battery positive (+) voltage applied to terminal G55-9 (MREL)
11 to 14 V
for 1KD-FTV:
Connect the cable to the negative (-) battery terminal.


Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Disconnect the G57, G58 and C93 ECM connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C93-1 (E1) - Body ground
Always
Below 1 Ω
C93-12 (E01) - Body ground
Always
Below 1 Ω
C93-13 (E02) - Body ground
Always
Below 1 Ω
C93-8 (ME01) - Body ground
Always
Below 1 Ω
G57-11 (EC) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G57-23 (BATT) - Body ground
Always
11 to 14 V
G57-17 (+B2) - Body ground
Battery positive (+) voltage applied to terminal G58-11 (MREL)
11 to 14 V
G57-24 (+B) - Body ground
Battery positive (+) voltage applied to terminal G58-11 (MREL)
11 to 14 V
| Result |
Proceed to |
| OK (for 1GR-FE) |
A |
| OK (for 1KD-FTV) |
B |
| NG |
C |
|
|
||||
|
|
||||
| A | ||
| ||