2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

INSPECTION

Inspection · Vehicles built from Aug 2013


INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)

E201017E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 - 2
    15°C (59°F)
    2.45 to 2.88 kΩ
    1 - 2
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 - 2
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 - 2
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 - 2
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 - 2
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 - 2
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 - 2
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 - 2
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 - 2
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

    If the result is not as specified, replace the cooler thermistor (room temperature sensor).
    Text in Illustration 
    *a
    Component without harness connected
    (Cooler Thermistor (Room Temperature Sensor))
    *b
    Resistance kΩ
    *c
    Temperature °C (°F)

← REMOVAL (from Aug 2013)INSTALLATION (from Aug 2013) →