2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

SYSTEM DESCRIPTION

Troubleshooting · Vehicles built from Aug 2013


GENERAL
  1. The air conditioning system has the following controls.

    Control
    Outline
    Neural Network Control
    This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship similar to that of a human brain.
    Outlet Air Temperature Control
    Based on the temperature set by the temperature control dial, neural network control calculates outlet air temperature based on input signals from various sensors.
    Pollen Removal Mode Control
    1. When the pollen removal mode switch is pressed, pollen removal mode control is activated and the air vent is switched to the FACE mode.
    2. Sends air, which is filtered by the clean air filter to remove pollen, to the area around the upper parts of the bodies of the driver and front passenger.
    Left and Right Independent Control
    The temperature settings for the driver and front passenger are controlled independently in order to provide separate vehicle interior temperatures for the right and left sides of the vehicle.
    Blower Control
    Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors.
    Air Outlet Control
    Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control.
    In accordance with the engine coolant temperature, ambient air temperature, amount of sunlight, required blower speed, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to foot and defroster mode to prevent the windows from becoming fogged up when the ambient air temperature is low.
    Air Inlet Control
    Automatically controls the air inlet control damper to help achieve the calculated outlet air temperature that is required.
    Drives the air inlet control servo motor according to the operation of the air inlet control switch and moves the dampers to the fresh or recirculation position.
    Compressor Control
    The air conditioning amplifier assembly compares the A/C pulley speed signals, which are transmitted by the ECM (crankshaft position sensor). When the air conditioning amplifier assembly determines that the A/C pulley is locked, it turns off the magnet clutch assembly.
    Defroster Control
    Defroster control logic is used to improve defroster performance.
    Rear Defogger Control
    When the ignition switch is ON and the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. However, the operating time of the rear defogger can be extended up to approx. 255 minutes when both of the following requirements are met:
    1. Ambient Temperature: -3°C (26.6°F) or less
    2. Vehicle Speed: 50 km/h (31.1 mph) or more
    Diagnosis
    A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system.


NEURAL NETWORK CONTROL
  1. Neural network control collects data under varying environmental conditions and stores it in the air conditioning amplifier assembly. Neural network control uses this data to enhance air conditioning control.
  2. Neural network control consists of neurons organized into an input layer, intermediate layer and output layer. The input layer neurons process the input data received from the switches and sensors, which includes the outside temperature, amount of sunlight and room temperature, and outputs this data to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The result is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. The air conditioning amplifier assembly then controls the servo motors and blower motor in accordance with the control volumes that have been calculated by neural network control.
E185705E02

POLLEN REMOVAL MODE CONTROL

  1. When the pollen removal mode switch is pressed, the pollen removal mode control is activated. Then, the air vent is switched to the FACE mode and recirculated pollen free air flows in the area around the upper parts of the bodies of the driver and front passenger.
    E116944E06

    1. When the pollen removal mode switch signal is input to the air conditioning amplifier assembly, the air conditioning amplifier assembly controls the magnet clutch assembly, recirculation damper servo sub-assembly, damper servo sub-assembly (mode damper servo) and blower with fan motor sub-assembly as shown in the timing chart.

    2. This control usually operates for approximately 3 minutes.

    3. After this control stops operating, the air conditioning amplifier assembly automatically returns to the mode it was in just before the pollen removal mode switch was pressed.


MODE POSITION AND DAMPER OPERATION

  1. Mode Position and Damper Operation

    1. Front Air Conditioning Unit
      E203282E02

      Function of Main Damper 
      Control Damper
      Operation Position
      Damper Position
      Operation
      Air Inlet Control Damper
      Fresh
      A
      Brings in fresh air.
      Recirculation
      B
      Recirculates internal air.
      Air Mix Control Damper
      MAX COOL to MAX HOT
      E - D - C
      E' - D' - C'
      Varies the mixture of cold air and hot air in order to regulate the temperature continuously from hot to cool.
      MAX COOL Damper
      MAX COOL
      V
      Open in the MAX COOL position.
      Except MAX COOL
      W
      Close in all position except MAX COOL position.
      MAX HOT Damper
      MAX HOT
      Y
      Open in the MAX HOT position.
      Except MAX HOT
      X
      Closed in all position except MAX HOT position.
      Mode Control Damper
      E106656
      Face
      F, I, N, T, X (FACE 1)
      F, J, N, T, X (FACE 2)
      Air blows out of the front center registers, side registers and rear face registers. (FACE 1)
      Air blows out of the front center registers, side registers and rear face registers. In addition, air blows out slightly from the front and rear footwell register ducts. (FACE 2)
      E106657
      Bi-level
      G, L, N, T, X
      Air blows out of the front center registers, side registers, rear face registers and front and rear footwell register ducts.
      E106658
      Foot
      H, M, P, T, W, Y (MAX HOT position)
      H, M, O, T, X (Except MAX HOT Position)
      Air blows out of the front and rear footwell register ducts.
      In addition, air blows out slightly from the front defroster, side registers, front center registers and rear face registers.
      E106659
      Foot/Def
      H, K, R, T, W, Y (MAX HOT position)
      H, M, Q, T, X (Except MAX HOT Position)
      Defrosts the windshield through the front defroster and side registers while air is also blown out from the front and rear footwell register ducts.
      In addition, air blows out slightly from the front center registers and rear face registers.
      E106660
      Def
      H, I, S, U, X
      Defrosts the windshield through the front defrosters.

    2. Rear Air Conditioning Unit (w/ Rear Air Conditioning System)
      E167995E03

      Function of Main Damper 
      Control Damper
      Operation Position
      Damper Position
      Operation
      Mode Control Damper
      E106656
      Face
      A
      Air blows out from the rear roof registers.
      E106657
      Bi-level
      B
      Air blows out from the rear roof registers and rear side registers.
      E106658
      Foot
      C
      Air blows out from the rear side registers.
      Air Mix Control Damper
      MAX COLD to MAX HOT Temperature Setting
      D, E
      Varies the mixture of cold air and hot air in order to regulate the temperature continuously from hot to cold.


AIR OUTLETS AND AIRFLOW VOLUME

  1. Air Outlets and Airflow Volume

    1. for Front Registers
      E195804E01

      Indication
      (Mode)
      Front Center Register
      Side Register
      Front Footwell Register
      Rear Face Register*
      Rear Footwell Register
      Front Defroster
      A
      B
      C
      D
      E
      F
      E106656
      Face 1
      E165952
      E165952
      -
      E155421
      -
      -
      E106656
      Face 2
      E165952
      E165952
      E155419
      E155421
      E155419
      -
      E106657
      Bi-level
      E155422
      E155422
      E155422
      E155421
      E155421
      -
      E106658
      Foot
      E155419
      E155419
      E165952
      E155419
      E155422
      E155419
      E106659
      Foot/Def
      E155419
      E155419
      E155422
      E155419
      E155422
      E155421
      E106660
      Def
      -
      -
      -
      -
      -
      E165952
      1. *: w/o Rear Air Conditioning System

      HINT:
      1. The size of the circle indicates the proportion of airflow volume.
      2. The same system is used for LHD and RHD vehicles.

    2. for Rear Registers (w/ Rear Air Conditioning System)
      E195803E01

      Indication
      (Mode)
      Rear Roof Register
      Rear Side Register
      A
      B
      E106656
      Face
      E165952
      -
      E106657
      Bi-level
      E155421
      E155419
      E106658
      Foot
      -
      E155422

      HINT:
      The size of the circle ○ indicates the ratio of airflow volume.


A/C LOCK SENSOR
The A/C lock sensor sends A/C pulley speed signals to the air conditioning amplifier assembly. The air conditioning amplifier assembly determines whether the cooler compressor assembly is locked or not by using those signals and engine speed signals.

No. 1 COOLER THERMISTOR
The No. 1 cooler thermistor detects the temperature of the cool air immediately after it passes through the evaporator in the form of resistance changes, and outputs the temperature to the air conditioning amplifier assembly.

BLOWER WITH FAN MOTOR SUB-ASSEMBLY
The blower with fan motor sub-assembly has a built-in blower controller and is controlled by the air conditioning amplifier assembly using duty control.

AIR CONDITIONING HARNESS ASSEMBLY (BUS CONNECTOR)

  1. A BUS connector is used in the wire harness that connects the servo motor to the air conditioning amplifier assembly.
    E195802E01

    Connector Type
    Connected to
    *1: Bus connector
    Damper servo sub-assembly LH (driver side air mix damper servo)
    *2: Bus connector
    Damper servo sub-assembly LH (mode damper servo)
    *3: Bus connector
    Damper servo sub-assembly RH (front passenger side air mix damper servo)
    *4: Bus connector
    Recirculation damper servo sub-assembly
    *5: Connector
    Air conditioning amplifier assembly
    *6: Connector
    No. 1 cooler thermistor
    *7: Bus connector
    Damper servo sub-assembly RH (driver side air mix damper servo)
    *8: Bus connector
    Damper servo sub-assembly LH (front passenger side air mix damper servo)

  2. Each BUS connector has a built-in communication/driver IC which communicates with each servo motor connector, actuates the servo motor, and has a position detection function.
    E187730E01


SERVO MOTOR

  1. The pulse pattern type servo motor detects the relative position using 2-bit on/off signals.
    The forward and reverse revolutions of this motor are detected using two signals, A and B, which output four types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.
    E187731E01


QUICK HEATER ASSEMBLY (w/ PTC Heater)

  1. General

    1. The PTC heater is located above the heater core in the air conditioner unit.

    2. The PTC heater consists of a PTC element, aluminum fins and brass plates. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.
      E203279E01

  2. PTC Heater Operating Conditions

    1. The on/off operation of the PTC heater is controlled by the air conditioning amplifier assembly in accordance with the engine coolant temperature, ambient temperature, engine speed, air mix setting and electrical load (generator power ratio).
      For example, the number of operating PTC heaters varies according to engine coolant temperature as shown in the graph below.
      E145149E05


VISCOUS WITH MAGNET CLUTCH HEATER ASSEMBLY (w/ Viscous Heater)
  1. The viscous with magnet clutch heater assembly, which is located on top of the engine, is driven by a drive belt. Pressing the heater switch assembly provided in the instrument panel engages the magnetic clutch, causing the rotor in the viscous with magnet clutch heater assembly to rotate and the silicon oil to mix. The shear heat that is thus generated heats the coolant.

  2. The viscous with magnet clutch heater assembly is controlled in accordance with the engine speed, coolant temperature and ambient temperature. While the power heater is engaged, the engine idling speed is raised to a predetermined value whenever the shift lever is in N or D.


COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
The cooler thermistor (room temperature sensor) detects the cabin temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.

COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
The cooler thermistor (ambient temperature sensor) detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.

AUTOMATIC LIGHT CONTROL SENSOR (SOLAR SENSOR)
  1. The automatic light control sensor (solar sensor) consists of a photo diode, 2 amplifier circuits for the solar sensor and a frequency converter circuit for the light control sensor.

  2. The automatic light control sensor (solar sensor) detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from the LH and RH sides (2 directions) and outputs these sunlight intensity signals to the air conditioning amplifier assembly.
    E116951E04

← SYSTEM DIAGRAM (from Aug 2013)HOW TO PROCEED WITH TROUBLESHOOTING (Aug 2013 – Jul 2014) →