B1411/11 Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The cooler thermistor (room temperature sensor) for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner auto mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1411/11 |
An open or short in the cooler thermistor (room temperature sensor) circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (ROOM TEMPERATURE SENSOR) |
Use the Data List to check if the cooler thermistor (room temperature sensor) is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Cooler thermistor (room temperature sensor) /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) |
Remove the cooler thermistor (room temperature sensor) (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
Text in Illustration *a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (refer to the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the G27 sensor connector.
Disconnect the G25 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
G27-1 - G25-29 (TR)
Always
Below 1 Ω
G27-2 - G25-34 (SG-1)
G25-29 (TR) - Body ground
Always
10 kΩ or higher
G25-34 (SG-1) - Body ground
|
|
||||
| OK | ||
| ||