2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

P115D Intake Manifold Runner Control Circuit Low (Bank 2)

Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014

Also covers:

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

Refer to DTC P2006 (Click here).
P115D 
DTC Detection Drive Pattern
DTC Detection Condition
Trouble Area
2 seconds after engine is started, race engine for 1 second
Open in vacuum switching valve (for No. 2 swirl control valve) circuit for 0.5 seconds (2 trip detection logic).
  1. Vacuum switching valve (for No. 2 swirl control valve)
  2. Open in vacuum switching valve (for No. 2 swirl control valve) circuit
  3. ECM
P115E 
DTC Detection Drive Pattern
DTC Detection Condition
Trouble Area
2 seconds after engine is started, race engine for 1 second
Short in vacuum switching valve (for No. 2 swirl control valve) circuit for 0.5 seconds (2 trip detection logic).
  1. Vacuum switching valve (for No. 2 swirl control valve)
  2. Short in vacuum switching valve (for No. 2 swirl control valve) circuit
  3. ECM

WIRING DIAGRAM

A249247E07

INSPECTION PROCEDURE

NOTICE:
  1. Inspect the fuses of circuits related to this system before performing the following inspection procedure.
  2. After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
  3. After replacing the fuel supply pump assembly, the ECM needs initialization (Click here).
  4. After replacing an injector assembly, the ECM needs registration (Click here).

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


1. INSPECT VACUUM SWITCHING VALVE FOR NO. 2 SWIRL CONTROL VALVE (RESISTANCE)
  1. Inspect the vacuum switching valve (for No. 2 swirl control valve) (Click here).



NG
Go to step 7
OK


2. INSPECT VACUUM SWITCHING VALVE (FOR SWIRL CONTROL VALVE) (POWER SOURCE VOLTAGE)

  1. A249191E03
    Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C79-2 - Body ground
    Engine switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Vacuum Switching Valve (for No. 2 Swirl Control Valve))



NG
Go to step 5
OK


3. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR SWIRL CONTROL VALVE) - ECM)
  1. Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    C79-1 - C93-3 (SCV2)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    C79-1 or C93-3 (SCV2) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the vacuum switching valve (for No. 2 swirl control valve) connector.

  1. Reconnect the ECM connector.



NG
Go to step 8
OK


4. REPLACE ECM
  1. Replace the ECM (Click here).



NEXT
Go to step 9
5. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR NO. 2 SWIRL CONTROL VALVE) - NO. 1 INTEGRATION RELAY)
  1. Remove the No. 1 integration relay from the engine room relay block.

  1. Disconnect the No. 1 integration relay connector.

  1. Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1B-8 - C79-2
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    1B-8 or C79-2 - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the No. 1 integration relay.

  1. Reconnect the No. 1 integration relay connector.

  1. Reconnect the vacuum switching valve (for No. 2 swirl control valve) connector.



NG
Go to step 8
OK


6. CHECK ECM POWER SOURCE CIRCUIT
  1. Check the ECM power source circuit (Click here).



NEXT
Go to step 9
7. REPLACE VACUUM SWITCHING VALVE (FOR NO. 2 SWIRL CONTROL VALVE)
  1. Replace the vacuum switching valve (for No. 2 swirl control valve) (Click here).



NEXT
Go to step 9
8. REPAIR OR REPLACE HARNESS OR CONNECTOR
  1. Repair or replace harness or connector.


NEXT


9. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
  1. Connect the intelligent tester to the DLC3.

  1. Clear the DTCs (Click here).

  1. Start the engine and wait for 3 seconds or more.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Confirm that the DTC is not output again.


NEXT

END


← P0724 Brake Switch "B" Circuit High (from Aug 2014)P115D Intake Manifold Runner Control Circuit Low (Bank 2) (+ P115E) (from Aug 2014) →