P115D Intake Manifold Runner Control Circuit Low (Bank 2)
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Also covers:
- P115E Intake Manifold Runner Control Circuit High (Bank 2)
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
Refer to DTC P2006 (Click here).| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| 2 seconds after engine is started, race engine for 1 second |
Open in vacuum switching valve (for No. 2 swirl control valve) circuit for 0.5 seconds (2 trip detection logic). |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| 2 seconds after engine is started, race engine for 1 second |
Short in vacuum switching valve (for No. 2 swirl control valve) circuit for 0.5 seconds (2 trip detection logic). |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- After replacing the fuel supply pump assembly, the ECM needs initialization (Click here).
- After replacing an injector assembly, the ECM needs registration (Click here).
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. INSPECT VACUUM SWITCHING VALVE FOR NO. 2 SWIRL CONTROL VALVE (RESISTANCE) |
Inspect the vacuum switching valve (for No. 2 swirl control valve) (Click here).
|
|
||||
| OK | |
| 2. INSPECT VACUUM SWITCHING VALVE (FOR SWIRL CONTROL VALVE) (POWER SOURCE VOLTAGE) |
Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
C79-2 - Body ground
Engine switch on (IG)
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to Vacuum Switching Valve (for No. 2 Swirl Control Valve))
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR SWIRL CONTROL VALVE) - ECM) |
Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.
Disconnect the ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
C79-1 - C93-3 (SCV2)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
C79-1 or C93-3 (SCV2) - Body ground
Always
10 kΩ or higher
Reconnect the vacuum switching valve (for No. 2 swirl control valve) connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 4. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 5. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR NO. 2 SWIRL CONTROL VALVE) - NO. 1 INTEGRATION RELAY) |
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the No. 1 integration relay connector.
Disconnect the vacuum switching valve (for No. 2 swirl control valve) connector.
Measure the resistance of the wire harness side connectors.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
1B-8 - C79-2
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
1B-8 or C79-2 - Body ground
Always
10 kΩ or higher
Reinstall the No. 1 integration relay.
Reconnect the No. 1 integration relay connector.
Reconnect the vacuum switching valve (for No. 2 swirl control valve) connector.
|
|
||||
| OK | |
| 6. CHECK ECM POWER SOURCE CIRCUIT |
Check the ECM power source circuit (Click here).
|
|
||||
| 7. REPLACE VACUUM SWITCHING VALVE (FOR NO. 2 SWIRL CONTROL VALVE) |
Replace the vacuum switching valve (for No. 2 swirl control valve) (Click here).
|
|
||||
| 8. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace harness or connector.
| NEXT | |
| 9. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the intelligent tester to the DLC3.
Clear the DTCs (Click here).
Start the engine and wait for 3 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Confirm that the DTC is not output again.
| NEXT | ||
| ||