INSTALLATION
Removal / installation · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
- HINT:
- A bolt without a torque specification is shown in the standard bolt chart (Click here).
- Use the same procedure for LHD and RHD vehicles.
- The procedure listed below is for LHD vehicles.
- A bolt without a torque specification is shown in the standard bolt chart (Click here).
| 1. INSTALL NETWORK GATEWAY ECU |
Attach the 2 claws to install the network gateway ECU to the ECU integration box RH.
| 2. INSTALL ECU INTEGRATION BOX RH |
Install the ECU integration box RH with the 2 nuts and bolt.
Attach the harness clamp.
Connect the connectors.
- NOTICE:
- Do not twist the connectors of ECU when connecting them.
- Do not apply more force than necessary to the connectors. If more than 98 N (10 kgf, 22 lbf) of force is applied to a connector, the connector or connector holder may be damaged.
- Do not twist the connectors of ECU when connecting them.
| 3. INSTALL NO. 2 AIR DUCT SUB-ASSEMBLY |
Attach the 2 claws to install the No. 2 air duct sub-assembly.
Install the screw.
| 4. INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY |
![]() ![]() |
Connect each connector.
Attach the 5 clips and claw to install the glove compartment door.
Install the 2 bolts <C> and 2 screws <A> or <B>.
Text in Illustration *1
Bolt
*2
Screw
| 5. INSTALL INSTRUMENT PANEL ORNAMENT |
Attach the 5 clips to install the instrument panel ornament.
| 6. INSTALL INSTRUMENT SIDE PANEL RH |
Connect the connector.
Attach the 5 clips, claw and 3 guides to install the instrument side panel.
| 7. INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY |
Attach the 3 clips and 2 guides to install the No. 2 instrument panel under cover.
Install the screw.


Text in Illustration *A
for LHD
*B
for RHD
| 8. INSTALL COWL SIDE TRIM BOARD RH |
- HINT:
- Use the same procedure described for the LH side.
for 3 Door: (Click here)
| 9. INSTALL DOOR SCUFF PLATE ASSEMBLY RH |
- HINT:
- Use the same procedure described for the LH side.
for 3 Door: (Click here)
| 10. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).