2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

INSPECTION

Inspection · Vehicles built from Aug 2013


INSPECT TRIP SWITCH (w/o TAIL Cancel Switch)

  1. Inspect the light control rheostat.

    1. Measure the resistance according to the value(s) in the table below.

      E195766E01

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ

  1. Inspect the ODO/TRIP switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      4 (A/B) - 1 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      1 (A/B) - 4 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher

      If the result is not as specified, replace the rheostat.


INSPECT TRIP SWITCH (w/ TAIL Cancel Switch)

  1. Inspect the light control rheostat.

    1. Measure the resistance according to the value(s) in the table below.

      E195765E01

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 6 (TC)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 100 Ω
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      7 (TC) - 8 (T)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 1 Ω
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ

  1. Inspect the ODO/TRIP switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      4 (A/B) - 1 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      1 (A/B) - 4 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher

      If the result is not as specified, replace the rheostat.