INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT TRIP SWITCH (w/o TAIL Cancel Switch) |
Inspect the light control rheostat.
Measure the resistance according to the value(s) in the table below.


- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
5 (T) - 1 (E)
Always
8 to 12 kΩ
7 (RV) - 1 (E)
Light control rheostat fully turned right → Light control rheostat fully turned left
Below 100 Ω → 8 to 12 kΩ
for RHD Tester Connection
Switch Condition
Specified Condition
8 (T) - 4 (E)
Always
8 to 12 kΩ
6 (RV) - 4 (E)
Light control rheostat fully turned right → Light control rheostat fully turned left
Below 100 Ω → 8 to 12 kΩ
Inspect the ODO/TRIP switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
4 (A/B) - 1 (E)
ODO/TRIP switch on (Pushed)
Below 1 Ω
ODO/TRIP switch off (Not pushed)
1 MΩ or higher
for RHD Tester Connection
Switch Condition
Specified Condition
1 (A/B) - 4 (E)
ODO/TRIP switch on (Pushed)
Below 1 Ω
ODO/TRIP switch off (Not pushed)
1 MΩ or higher
| INSPECT TRIP SWITCH (w/ TAIL Cancel Switch) |
Inspect the light control rheostat.
Measure the resistance according to the value(s) in the table below.


- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
5 (T) - 6 (TC)
TAIL cancel switch off → on
1 MΩ or higher → Below 100 Ω
5 (T) - 1 (E)
Always
8 to 12 kΩ
7 (RV) - 1 (E)
Light control rheostat fully turned right → Light control rheostat fully turned left
Below 100 Ω → 8 to 12 kΩ
for RHD Tester Connection
Switch Condition
Specified Condition
7 (TC) - 8 (T)
TAIL cancel switch off → on
1 MΩ or higher → Below 1 Ω
8 (T) - 4 (E)
Always
8 to 12 kΩ
6 (RV) - 4 (E)
Light control rheostat fully turned right → Light control rheostat fully turned left
Below 100 Ω → 8 to 12 kΩ
Inspect the ODO/TRIP switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
4 (A/B) - 1 (E)
ODO/TRIP switch on (Pushed)
Below 1 Ω
ODO/TRIP switch off (Not pushed)
1 MΩ or higher
for RHD Tester Connection
Switch Condition
Specified Condition
1 (A/B) - 4 (E)
ODO/TRIP switch on (Pushed)
Below 1 Ω
ODO/TRIP switch off (Not pushed)
1 MΩ or higher