2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

REMOVAL

Removal / installation · Vehicles built Aug 2013 – Jul 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

HINT:
  1. Use the same procedure for RHD and LHD vehicles.
  2. The procedure listed below is for LHD vehicles.


1. DISABLE AUTOAWAY/RETURN FUNCTION (for Power Tilt and Power Telescopic Steering Column)
  1. Disable the Autoaway/Return function by changing the customize parameter (Click here).

    NOTICE:
    Record the current customize parameter setting (whether the Autoaway/Return function is enabled or disabled) in order to restore the current setting after finishing the operation.

    HINT:
    Performing the above operation causes the Autoaway/Return function to be disabled when the ignition switch is turned off.

  1. Turn the ignition switch to ON. Operate the tilt and telescopic switch to fully extend and lower the steering column.

  1. Turn the ignition switch off.


2. PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).


3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


4. REMOVE INSTRUMENT CLUSTER FINISH PANEL ORNAMENT (for LHD)

B238207E01
  1. Put protective tape around the instrument cluster finish panel ornament.

    Text in Illustration 
    *1
    Protective Tape

  1. Using a moulding remover, detach the 3 clips and remove the instrument cluster finish panel ornament.


5. REMOVE INSTRUMENT PANEL FINISH PLATE GARNISH (for RHD)

B238239
  1. Detach the 4 clips.

  1. Disconnect each connector and remove the instrument panel finish plate garnish.


6. REMOVE LOWER INSTRUMENT PANEL FINISH PANEL ASSEMBLY

B238214
  1. Detach the 4 clips.

  1. Disconnect each connector and remove the instrument panel finish panel.


7. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

  1. E198219E01
    Place protective tape as shown in the illustration.
    Text in Illustration 
    *1
    Protective Tape

  1. Detach the 4 claws.

  1. E198220
    Detach the 4 claws.

  1. Detach the 2 clips and 2 guides.

  1. Disconnect the connector and remove the instrument cluster finish panel sub-assembly.


8. REMOVE COMBINATION METER ASSEMBLY

  1. E194816
    Remove the 4 screws and combination meter assembly.

  1. Disconnect the 2 connectors.