2013-2015 Land Cruiser Prado · Service Manual Power Source / Network

Power Management Control ECU Communication Stop Mode

Circuit diagnosis · Vehicles built from Aug 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

Detection Item
Symptom
Trouble Area
Power Management Control ECU Communication Stop Mode
Either condition is met:
  1. "Power Management1" is not displayed on "Bus Check".
  2. "Power Management Control ECU Communication Stop Mode" in "DTC Combination Table" applies.
  1. Power source or inside power management control ECU
  2. Power management control ECU CAN branch wire or connector
  3. Power management control ECU

WIRING DIAGRAM

C201306E11

INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Operating the engine switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.


1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the airbag system.

    NOTICE:
    1. After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
    2. When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


2. CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU CAN BRANCH WIRE)

  1. C198951E25
    Disconnect the G51 power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    G51-14 (CA1H) - G51-13 (CA1L)
    Engine switch off
    54 to 69 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)



NG
REPAIR OR REPLACE POWER MANAGEMENT CONTROL ECU CAN BRANCH WIRE OR CONNECTOR (CA1H, CA1L)
OK


3. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY AND BODY GROUND)

  1. C198951E24
    Connect the cable to the negative (-) battery terminal.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G51-5 (GND2) - Body ground
    Always
    Below 1 Ω
    G51-6 (GND) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G51-1 (AM22) - Body ground
    Always
    11 to 14 V
    G51-2 (AM21) - Body ground
    Always
    11 to 14 V

Text in Illustration 
*a
Rear view of wire harness connector
(to Power Management Control ECU)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)


← Power Management Control ECU Communication Stop Mode (Aug 2013 – Jul 2014)Combination Meter ECU Communication Stop Mode (Aug 2013 – Jul 2014) →