P245C EGR Cooler Bypass Control Circuit Low
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Also covers:
- P245D EGR Cooler Bypass Control Circuit High
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The vacuum switching valve (for EGR bypass valve) is controlled by the ECM, and the opening and closing of the EGR cooler bypass valve is performed according to the vacuum applied by the vacuum pump.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds |
Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic). |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds |
Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic). |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
| 1. INSPECT VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) |
Inspect the vacuum switching valve (for EGR bypass valve) (Click here).
|
|
||||
| OK | |
| 2. CHECK VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) (POWER SOURCE CIRCUIT) |
Disconnect the vacuum switching valve (for EGR bypass valve) connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
C78-1 - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to Vacuum Switching Valve (for EGR Bypass Valve))
Reconnect the vacuum switching valve (for EGR bypass valve) connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) - ECM) |
Disconnect the vacuum switching valve (for EGR bypass valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
C78-2 - C93-4 (ECBV)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
C78-2 or C93-4 (ECBV) - Body ground
Always
10 kΩ or higher
Reconnect the vacuum switching valve (for EGR bypass valve) connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 4. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 5. REPLACE VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) |
Replace the vacuum switching valve (for EGR bypass valve).
|
|
||||
| 6. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace the harness or connector.
- HINT:
- If the voltage at the vacuum switching valve (for EGR bypass valve) connector is not 11 to 14 V, repair or replace the harness and connector between the vacuum switching valve (for EGR bypass valve) and EFI relay (including the EFI No. 2 fuse).
| NEXT | |
| 7. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the intelligent tester to the DLC3.
Clear the DTCs (Click here).
Turn the ignition switch to ON for 3 seconds.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Confirm that the DTC is not output again.
| NEXT | ||
| ||