Vehicle Speed Signal Circuit between Navigation Receiver Assembly and Combination Meter
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The navigation receiver assembly receives a vehicle speed signal from the combination meter assembly to control the ASL function.- HINT:
- A voltage of 12 V or 5 V is output from each ECU and then input to the combination meter assembly. The signal is changed to a pulse signal at the transistor in the combination meter assembly. Each ECU controls the respective systems based on the pulse signal.
- If a short occurs in any of the ECUs or in the wire harness connected to an ECU, all systems in the diagram below will not operate normally.
- A voltage of 12 V or 5 V is output from each ECU and then input to the combination meter assembly. The signal is changed to a pulse signal at the transistor in the combination meter assembly. Each ECU controls the respective systems based on the pulse signal.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK COMBINATION METER ASSEMBLY (OUTPUT WAVEFORM) |
Check the output waveform.

Remove the combination meter assembly with the connector(s) still connected.
Connect an oscilloscope to terminal G6-32 (+S) and body ground.
Turn the engine switch on (IG).
Turn a wheel slowly.
Check the signal waveform according to the condition(s) in the table below.
Item
Condition
Measurement terminal
G6-32 (+S) - Body ground
Tool setting
5 V/DIV., 20 ms./DIV.
Vehicle condition
Wheel being rotated
- OK:
- The waveform is similar to that shown in the illustration.
- HINT:
- When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.
Text in Illustration *a
Component with harness connected
(Combination Meter Assembly)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (NAVIGATION RECEIVER ASSEMBLY - COMBINATION METER ASSEMBLY) |
Disconnect the H61 navigation receiver assembly connector.
Disconnect the G6 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
H61-17 (SPD) - G6-32 (+S)
Always
Below 1 Ω
H61-17 (SPD) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||