Disconnect the G55*1, G56*2, G58*3, G180*4 or G184*5 ECM connector.
*1: for 1GR-FE, Automatic Transmission
*2: for 1GR-FE, Manual Transmission
*3: for 1KD-FTV
*4: for 2TR-FE
*5: for 1GD-FTV
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G48-13 (TC) - G55-6 (TC) | Always | Below 1 Ω |
| G48-4 (CG) - Body ground | ||
| G48-13 (TC) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G48-13 (TC) - G56-28 (TC) | Always | Below 1 Ω |
| G48-4 (CG) - Body ground | ||
| G48-13 (TC) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G48-13 (TC) - G58-23 (TC) | Always | Below 1 Ω |
| G48-4 (CG) - Body ground | ||
| G48-13 (TC) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G48-13 (TC) - G180-19 (TC) | Always | Below 1 Ω |
| G48-4 (CG) - Body ground | ||
| G48-13 (TC) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G184-25 (TC) - G58-23 (TC) | Always | Below 1 Ω |
| G48-4 (CG) - Body ground | ||
| G48-13 (TC) - Body ground | Always | 10 kΩ or higher |
OK
NG