Home › Drivetrain › A750F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV) › 2015.06–2020.08
RM27T0E _52 Drivetrain _053697 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0260766 AUTOMATIC TRANSMISSION SYSTEM(for 1KD-FTV) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1KD-FTV)  P0778  Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the TCM. If an open or short circuit occurs in one of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV)>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0778 The TCM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1-trip detection logic).
Output signal duty ratio equals 100%.
HINT:

SL2 output signal duty is less than 100% under normal conditions.


·

Open or short in shift solenoid valve SL2 circuit

·

Shift solenoid valve SL2

·

TCM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The TCM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. Then the TCM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In the case of an open or short circuit, the TCM stops sending current to the circuit.

While driving and shifting gears, if the TCM detects an open or short in the shift solenoid valve SL2 circuit, the TCM determines there is a malfunction (See page Drivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV)>FAIL-SAFE CHART).

WIRING DIAGRAM

C219217E54
2.802,1.333 3.031,1.5 0.229,0.167 10 false 11 5.531,1.354 5.76,1.521 0.229,0.167 10 false 7 2.323,1.063 2.75,1.26 0.427,0.198 10 false SL2+ 2.813,2.552 3.042,2.719 0.229,0.167 10 false 3 0.823,2.219 1.052,2.385 0.229,0.167 10 false 2 0.823,1.396 1.052,1.563 0.229,0.167 10 false 1 2.354,2.281 2.781,2.479 0.427,0.198 10 false SL2- 5.781,1.229 6.208,1.427 0.427,0.198 10 false SL2+ 5.542,2.573 5.771,2.74 0.229,0.167 10 false 6 5.781,2.438 6.208,2.635 0.427,0.198 10 false SL2- 1.021,2.938 1.448,3.135 0.427,0.198 10 false C30 1.021,3.104 2.271,3.302 1.25,0.198 10 false Transmission Wire 1.042,1.813 2.688,2.042 1.646,0.229 10 false Shift Solenoid Valve SL2 5.958,3.219 6.302,3.385 0.344,0.167 10 false G69 5.958,3.375 6.385,3.573 0.427,0.198 10 false TCM

CAUTION / NOTICE / HINT

HINT:

Shift solenoid valve SL2 is turned ON/OFF normally when the shift lever is in D.

TCM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SL2 ON ON ON ON OFF


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)
a.
C214326E03
1.868,1.306 1.669,1.745 false 1.941,1.087 2.195,1.745 false 1.432,1.783 1.795,1.950 0.363,0.167 10 SL2+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 2.056,1.783 2.398,1.950 0.343,0.167 10 SL2-

Disconnect the C30 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
11 (SL2+) - 3 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
11 (SL2+) - Body ground 20°C (68°F) 10 kΩ or higher
3 (SL2-) - Body ground 20°C (68°F) 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL2
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.
U169978E02
0.969,1.979 1.708,2.781 false 0.917,1.979 0.542,2.781 false 0.073,0 0.271,0.167 0.198,0.167 10 false *a 0.865,0.385 1.167,0.542 0.302,0.156 10 false G69 0.177,2.792 0.885,3.021 0.708,0.229 10 false 7 (SL2+) 1.469,2.792 2.104,3.01 0.635,0.219 10 false 6 (SL2-)

Disconnect the G69 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G69-7 (SL2+) - G69-6 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
G69-7 (SL2+) - Body ground 20°C (68°F) 10 kΩ or higher
G69-6 (SL2-) - Body ground 20°C (68°F) 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to TCM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR