Home › Drivetrain › AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)
RM27T0E _52 Drivetrain _053698 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0260769 AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FE) C

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FE)  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

Refer to the system description for DTC P2757 (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)>P2757).

DTC No. DTC Detection Condition Trouble Area
P2759 Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic).
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

ECM



MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will illuminate the MIL and store this DTC.

WIRING DIAGRAM

C358476E05
3.458,1.115 4.073,1.313 0.615,0.198 10 false SLU+ 5.198,1.115 5.813,1.313 0.615,0.198 10 false SLU+ 3.448,2.083 4.063,2.281 0.615,0.198 10 false SLU- 5.177,2.083 5.792,2.281 0.615,0.198 10 false SLU- 1.104,1.313 1.26,1.51 0.156,0.198 10 false 1 1.094,2.135 1.25,2.333 0.156,0.198 10 false 2 1.563,2.729 1.938,2.917 0.375,0.188 10 false C146 1.573,2.906 2.896,3.094 1.323,0.188 10 false Transmission Wire 1.469,1.729 3.063,1.927 1.594,0.198 10 false Shift Solenoid Valve SLU 3.938,1.115 4.25,1.313 0.313,0.198 10 false 21 4.979,1.115 5.135,1.313 0.156,0.198 10 false 2 3.927,2.083 4.24,2.281 0.313,0.198 10 false 22 4.979,2.083 5.135,2.281 0.156,0.198 10 false 1 5.583,3.052 6.198,3.25 0.615,0.198 10 false C155 5.604,3.229 6.063,3.427 0.458,0.198 10 false ECM 5.75,0.771 6.156,0.979 0.406,0.208 10 false 12 V

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transmission are replaced (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.



PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C319326E08
2.661,1.7 2.437,1.334 false 0.122,0.069 0.547,0.271 0.425,0.202 10 *a 1.841,1.748 2.267,1.950 0.425,0.202 10 SLU- 2.496,1.748 2.922,1.950 0.425,0.202 10 SLU+ 2.055,1.7 2.28,1.334 false

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
21 (SLU+) - 22 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
21 (SLU+) - Body ground Always 10 kΩ or higher
22 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLU
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U170449E02
1.917,1.635 1.375,2.656 false 2,1.635 2.552,2.656 false 0.948,2.677 1.729,2.885 0.781,0.208 10 false 2 (SLU+) 2.208,2.677 2.99,2.885 0.781,0.208 10 false 1 (SLU-) 1.573,0.188 2.083,0.396 0.51,0.208 10 false C155 0.073,0.073 0.583,0.281 0.51,0.208 10 false *a

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C155-2 (SLU+) - C155-1 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
C155-2 (SLU+) - Body ground Always 10 kΩ or higher
C155-1 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLU
a.
C197715E42
1.74,0.99 2.208,0.365 false 1.479,0.99 1.052,0.365 false 1.76,2.948 2.208,2.354 false 1.51,2.948 1.052,2.354 false 0.073,0.073 0.385,0.271 0.313,0.198 10 false *1 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

Remove shift solenoid valve SLU (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>DISASSEMBLY).


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Text in Illustration
*1 Shift Solenoid Valve SLU


OK

NG