Home › Drivetrain › AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)
RM27T0E _52 Drivetrain _053698 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0260769 AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FE) C

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FE)  P0748  Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)  


DESCRIPTION

Changing from 1st to 6th is performed by the ECM turning shift solenoid valves SL1, SL2, SL3 and SL4 on and off. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)>FAIL-SAFE CHART).

DTC No. DTC Detection Condition Trouble Area
P0748 An open or short circuit (output signal duty is 0% or 100%) is detected by the ECM in the shift solenoid valve SL1 circuit while driving and shifting gears (SL1 output signal duty is more than 0% and less than 100% under normal conditions) (1 trip detection logic).
·

Open or short in shift solenoid valve SL1 circuit

·

Shift solenoid valve SL1

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any of the shift solenoid valve circuits, the ECM detects the problem and illuminates the MIL and stores the DTC. The ECM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the ECM stops sending current to the circuit.)

While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines there is a malfunction (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C358476E01
3.458,1.115 4.073,1.313 0.615,0.198 10 false SL1+ 5.198,1.115 5.813,1.313 0.615,0.198 10 false SL1+ 3.448,2.083 4.063,2.281 0.615,0.198 10 false SL1- 5.177,2.083 5.792,2.281 0.615,0.198 10 false SL1- 1.104,1.313 1.26,1.51 0.156,0.198 10 false 1 1.094,2.135 1.25,2.333 0.156,0.198 10 false 2 1.563,2.729 1.938,2.917 0.375,0.188 10 false C146 1.573,2.906 2.896,3.094 1.323,0.188 10 false Transmission Wire 1.469,1.729 3.063,1.927 1.594,0.198 10 false Shift Solenoid Valve SL1 3.938,1.115 4.25,1.313 0.313,0.198 10 false 25 4.979,1.115 5.135,1.313 0.156,0.198 10 false 9 3.927,2.083 4.24,2.281 0.313,0.198 10 false 26 4.979,2.083 5.135,2.281 0.156,0.198 10 false 8 5.583,3.052 6.198,3.25 0.615,0.198 10 false C155 5.604,3.229 6.063,3.427 0.458,0.198 10 false ECM 5.75,0.771 6.156,0.979 0.406,0.208 10 false 12 V

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transmission are replaced (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE)>PRECAUTION).


HINT:
·

The following table shows normal operation of the shift solenoid valve SL1 when the shift lever is in D:

ECM commanded gear 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL1 ON ON ON ON OFF OFF

·

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.




PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1)
a.
C319326E03
2.074,1.7 1.85,1.334 false 0.122,0.069 0.547,0.271 0.425,0.202 10 *a 1.254,1.748 1.680,1.950 0.426,0.202 10 SL1- 1.91,1.748 2.335,1.950 0.425,0.202 10 SL1+ 1.468,1.7 1.693,1.334 false

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
25 (SL1+) - 26 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
25 (SL1+) - Body ground Always 10 kΩ or higher
26 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL1
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U170444E02
1.958,1.719 1.417,2.656 false 2.021,1.719 2.573,2.656 false 0.99,2.677 1.771,2.885 0.781,0.208 10 false 9 (SL1+) 2.219,2.677 3,2.885 0.781,0.208 10 false 8 (SL1-) 1.583,0.188 2.094,0.396 0.51,0.208 10 false C155 0.073,0.073 0.292,0.25 0.219,0.177 10 false *a

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C155-9 (SL1+) - C155-8 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
C155-9 (SL1+) - Body ground Always 10 kΩ or higher
C155-8 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL1
a.
C197715E42
1.74,0.99 2.208,0.365 false 1.479,0.99 1.052,0.365 false 1.76,2.948 2.208,2.354 false 1.51,2.948 1.052,2.354 false 0.073,0.073 0.385,0.271 0.313,0.198 10 false *1 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

Remove shift solenoid valve SL1 (See page Drivetrain>AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>DISASSEMBLY).


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Text in Illustration
*1 Shift Solenoid Valve SL1


OK

NG