Home › Drivetrain › AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY › 2015.06–2020.08
RM27T0E _52 Drivetrain _053698 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0260774 VALVE BODY ASSEMBLY G

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE SL1

a.
C197715E55
1.76,0.958 2.208,0.375 true 1.49,0.958 1.031,0.375 true 1.76,2.948 2.208,2.354 true 1.49,2.948 1.031,2.354 true 0.052,0.01 0.365,0.208 0.313,0.198 10 false *a 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL1)

If the value is not as specified, replace the shift solenoid valve SL1.


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the operation cannot be done as specified, replace the shift solenoid valve SL1.


Hide 2.INSPECT SHIFT SOLENOID VALVE SL2

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 3.INSPECT SHIFT SOLENOID VALVE SL3

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 4.INSPECT SHIFT SOLENOID VALVE SL4

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 5.INSPECT SHIFT SOLENOID VALVE SLU

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 6.INSPECT SHIFT SOLENOID VALVE SLT

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 7.INSPECT SHIFT SOLENOID VALVE SL

a.
C320237E02
0.125,0.061 0.550,0.263 0.425,0.202 10 *a 2.531,1.373 2.776,1.575 0.245,0.202 10 (+) 3.175,1.373 3.377,1.575 0.202,0.202 10 (-)

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL)

If the value is not as specified, replace the shift solenoid valve SL.


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SL connector

·

Battery negative (-) → Shift solenoid valve SL body


Valve moves and makes an operating noise