Home › Suspension › SUSPENSION CONTROL › HEIGHT CONTROL COMPRESSOR
RM27T0E _53 Suspension _053706 SUSPENSION CONTROL _0260873 HEIGHT CONTROL COMPRESSOR G

SUSPENSION CONTROL  HEIGHT CONTROL COMPRESSOR  INSPECTION  


PROCEDURE

Hide 48910B 1.INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)

a.
C216447E01
2.415,1.683 2.538,1.848 0.123,0.165 10 B 1.481,1.245 1.481,1.84 1.481,1.84 0.943,1.84 false 2.088,1.176 2.088,1.766 2.088,1.766 2.386,1.766 false 0.816,1.763 0.940,1.928 0.123,0.165 10 L 0.115,0.102 0.333,0.313 0.218,0.211 12 *a

Measure the resistance of the exhaust valve.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (L) - 1 (B) 15 to 25°C (59 to 77°F) 10 to 14 Ω


Text in Illustration
*a Component without harness connected
(Exhaust Valve)



b.
C216447E02
1.407,1.219 1.407,1.872 1.407,1.872 0.994,1.872 false 2.094,1.162 2.094,1.723 2.094,1.723 2.552,1.723 false 2.598,1.631 2.780,1.820 0.181,0.188 10 (-) 0.135,0.107 0.346,0.305 0.211,0.198 12 *a 0.736,1.777 0.978,1.940 0.242,0.163 10 (+)

Check the exhaust valve operation.

i.

Connect a positive (+) lead from the battery to terminal 2 (B), and a negative (-) lead to terminal 1 (L).


ii.

Check the operating sound of the height control valve.

OK:

It makes an operating sound.


Text in Illustration
*a Component without harness connected
(Exhaust Valve)

If the result is not as specified, replace the height control compressor.



Hide 48910B 2.INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)

a.

Check the compressor operation.

i.
C214513E10
1.927,1.063 2.188,0.719 2.188,0.719 2.396,0.719 false 1.531,1.031 1.188,0.719 false 1.188,0.719 1.063,0.719 false 0.083,0.073 0.271,0.25 0.188,0.177 12 false *a 2.479,0.625 2.604,0.771 0.125,0.146 10 false B 0.917,0.646 1.042,0.802 0.125,0.156 10 false E

Apply 12 V battery voltage to the compressor motor and check the operation of the motor.

OK:
Measurement Condition Specified Value
12 V battery positive (+) → Terminal 1 (B)
12 V battery negative (-) → Terminal 2 (E)
Motor operates


Text in Illustration
*a Component without harness connected
(Compressor Motor)

NOTICE:
·

Do not operate the height control compressor for 60 seconds or more.

·

Stop applying voltage immediately if the compressor stops operating because a short will occur and the compressor motor will lock up, causing a flow of excessive current.



If the result is not as specified, replace the height control compressor.