48910B
1.INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)
Measure the resistance of the exhaust valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (L) - 1 (B) | 15 to 25°C (59 to 77°F) | 10 to 14 Ω |
| *a | Component without harness connected
(Exhaust Valve) |
Check the exhaust valve operation.
Connect a positive (+) lead from the battery to terminal 2 (B), and a negative (-) lead to terminal 1 (L).
Check the operating sound of the height control valve.
It makes an operating sound.
| *a | Component without harness connected
(Exhaust Valve) |
If the result is not as specified, replace the height control compressor.
48910B
2.INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)
Check the compressor operation.
Apply 12 V battery voltage to the compressor motor and check the operation of the motor.
| Measurement Condition | Specified Value |
|---|---|
| 12 V battery positive (+) → Terminal 1 (B)
12 V battery negative (-) → Terminal 2 (E) |
Motor operates |
| *a | Component without harness connected
(Compressor Motor) |
Do not operate the height control compressor for 60 seconds or more.
Stop applying voltage immediately if the compressor stops operating because a short will occur and the compressor motor will lock up, causing a flow of excessive current.