48960
1.INSTALL NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY
Install the No. 2 height control valve with the 2 bolts.
2.CONNECT HEIGHT CONTROL TUBE
Connect the 3 height control tubes (See page Suspension>SUSPENSION CONTROL>SUSPENSION CONTROL SYSTEM (w/ Air Suspension)>PRECAUTION).
For the connection procedure of the tubes (type 1 and type 2), refer to Precaution of the Suspension Control System section.
Connect the connector.
3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
4.CHECK CONNECTION OF TUBE FOR AIR LEAK