89191A
1.INSPECT FRONT ACCELERATION SENSOR
Connect 3 dry batteries of 1.5 V in series.
Connect the positive (+) end of the batteries to terminal 3 (SBR) of the acceleration sensor and the negative (-) end of the batteries to terminal 2 (SGR). Then measure the voltage between terminal 1 (SGFR) and terminal 2 (SGR).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Sensor Condition | Specified Condition |
|---|---|---|
| 1 (SGFR) - 2 (SGR) | Sensor stationary | Approx. 2.0 to 2.5 V |
| Sensor tilted | Changes between approx. 0.9 and 2.3 V |
| *a | Component without harness connected
(Front Acceleration Sensor) |
|
Top |
|
Bottom |
When the front acceleration sensor is tilted, it may output a different value.
Do not apply higher than 6 V.
Do not drop the front acceleration sensor. If it is dropped, replace it with a new one.
Never place the front acceleration sensor upside down.
If the result is not as specified, replace the front acceleration sensor.