Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System) › 2015.06–2017.08
RM27T0E _57 Power Source / Network _053729 NETWORKING _0261033 CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System) C

NETWORKING  CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System)  U010E/A2  Lost Communication with Reductant Control Module  


DESCRIPTION

DTC Code DTC Detection Condition Trouble Area
U010E There is no communication from the urea pump control ECU.
·

Power source or inside of urea pump control ECU

·

Urea pump control ECU



For vehicle with a urea SCR system.


WIRING DIAGRAM

C329298E02
4.594,5.229 6.781,5.427 2.188,0.198 10 false Urea Pump Control ECU 5.292,0.448 5.906,0.646 0.615,0.198 10 false BATT 5.26,3.51 5.875,3.708 0.615,0.198 10 false IGSW 5.281,3.99 5.896,4.188 0.615,0.198 10 false E01 5.281,4.354 5.896,4.552 0.615,0.198 10 false E02 5.281,4.708 5.896,4.906 0.615,0.198 10 false E03 4.125,0.302 4.896,0.5 0.771,0.198 10 false DCU-B 4.26,3.323 5.031,3.521 0.771,0.198 10 false IGN 2.51,0.406 3.281,0.604 0.771,0.198 10 false from Battery 2.302,0.969 3.375,1.198 1.073,0.229 10 false from DCU Relay 5,3.854 5.313,4.052 0.313,0.198 10 false 52 5,4.208 5.313,4.406 0.313,0.198 10 false 51 5,4.542 5.313,4.74 0.313,0.198 10 false 50 4.99,3.365 5.302,3.563 0.313,0.198 10 false 18 5.01,0.302 5.323,0.5 0.313,0.198 10 false 30 4.594,5.031 4.906,5.229 0.313,0.198 10 false s4 5.292,0.99 5.906,1.188 0.615,0.198 10 false +BU1 5.292,1.302 5.906,1.5 0.615,0.198 10 false +BU2 5.292,1.625 5.906,1.823 0.615,0.198 10 false +BU3 5.281,2.115 5.896,2.313 0.615,0.198 10 false +BU4 5.292,2.458 5.906,2.656 0.615,0.198 10 false +BU5 4.99,0.844 5.302,1.042 0.313,0.198 10 false 11 4.99,1.167 5.302,1.365 0.313,0.198 10 false 10 4.979,1.479 5.292,1.677 0.313,0.198 10 false 19 5.073,1.979 5.385,2.177 0.313,0.198 10 false 1 5.073,2.313 5.385,2.51 0.313,0.198 10 false 2 5.073,2.813 5.385,3.01 0.313,0.198 10 false 9 5.292,2.958 5.906,3.156 0.615,0.198 10 false UREL 4.042,1.927 4.813,2.125 0.771,0.198 10 false DCU NO.1 4.031,0.802 4.802,1 0.771,0.198 10 false DCU NO.2 2.458,2.927 3.375,3.125 0.917,0.198 10 false to DCU Relay 2.396,3.49 3.333,3.688 0.938,0.198 10 false from IG2 Relay

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (UREA PUMP CONTROL ECU - BATTERY AND BODY GROUND)
a.
U170261E02
2.188,0.146 2.26,0.146 2.26,0.146 2.479,0.802 true 2.563,0.813 2.76,0.188 2.76,0.188 2.854,0.188 true 2.615,0.896 2.885,0.417 2.885,0.417 2.938,0.417 true 2.573,1.063 2.875,1.406 2.875,1.406 2.917,1.406 true 1.781,0.333 1.865,0.333 1.865,0.333 2.354,0.802 true 0.802,0.281 0.885,0.281 0.885,0.281 1.615,0.781 true 0.615,0.5 0.698,0.5 0.698,0.5 1.479,0.802 true 0.823,2.073 0.896,2.073 0.896,2.073 1.615,1.542 true 2.469,0.958 2.448,1.979 2.448,1.979 2.49,1.979 true 1.75,1.51 1.771,2 1.771,2 1.823,2 true 0.615,1.792 0.698,1.792 0.698,1.792 1.51,1.531 true 0.302,1.083 0.573,1.229 0.271,0.146 10 false s4 0.063,0.042 0.323,0.188 0.26,0.146 10 false *a 2.948,1.323 3.354,1.469 0.406,0.146 10 false BATT 2.906,0.104 3.313,0.25 0.406,0.146 10 false +BU1 1.74,0.063 2.146,0.208 0.406,0.146 10 false +BU2 2.969,0.333 3.375,0.479 0.406,0.146 10 false +BU3 0.125,0.438 0.531,0.583 0.406,0.146 10 false +BU4 0.313,0.188 0.719,0.333 0.406,0.146 10 false +BU5 1.333,0.26 1.74,0.406 0.406,0.146 10 false UREL 2.552,1.896 2.958,2.042 0.406,0.146 10 false IGSW 1.865,1.896 2.177,2.042 0.313,0.146 10 false E01 0.469,1.969 0.781,2.115 0.313,0.146 10 false E02 0.271,1.698 0.583,1.844 0.313,0.146 10 false E03

Disconnect the urea pump control ECU connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s4-52 (E01) - Body ground Always Below 1 Ω
s4-51 (E02) - Body ground Always Below 1 Ω
s4-50 (E03) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
s4-30 (BATT) - Body ground Always 11 to 14 V
s4-11 (+BU1) - Body ground Battery positive (+) voltage applied to terminal s4-9 (UREL) 11 to 14 V
s4-10 (+BU2) - Body ground Battery positive (+) voltage applied to terminal s4-9 (UREL) 11 to 14 V
s4-19 (+BU3) - Body ground Battery positive (+) voltage applied to terminal s4-9 (UREL) 11 to 14 V
s4-1 (+BU4) - Body ground Battery positive (+) voltage applied to terminal s4-9 (UREL) 11 to 14 V
s4-2 (+BU5) - Body ground Battery positive (+) voltage applied to terminal s4-9 (UREL) 11 to 14 V
s4-18 (IGSW) - Body ground Engine switch on (IG) 11 to 14 V



Text in Illustration
*a Front view of wire harness connector
(to Urea Pump Control ECU)


OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR