The main body ECU (multiplex network body ECU) receives switch signals from the multiplex network master switch, and key-linked switch signals from the front door lock. The main body ECU (multiplex network body ECU) activates the door lock motor on each door according to these signals.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Since the power door lock control system has functions that use LIN communication, first confirm that there is no malfunction in the communication system by inspecting the LIN communication functions in accordance with the "How to Proceed with Troubleshooting" procedures. Then, conduct the following inspection procedure.
Check the door lock operation.
| Result | Proceed to |
|---|---|
| No doors can be locked using multiplex network master switch | A |
| No doors can be locked using key-linked switch | B |
A
B
Use the Data List to check if the door key-linked switches is functioning properly (See page Vehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Door Key SW-Lock | Driver side door key-linked switch lock signal / ON or OFF | ON: Driver side door key cylinder turned to lock position
OFF: Driver side door key cylinder not turned to lock position |
- |
| D Door Key SW-UL | Driver side door key-linked switch unlock signal / ON or OFF | ON: Driver side door key cylinder turned to unlock position
OFF: Driver side door key cylinder not turned to unlock position |
- |
On tester screen, each item changes between ON and OFF according to above chart.
OK
NG
Remove the front door lock (See page Vehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Off | - | - |
|
Lock |
|
Unlock |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (L) - 7 (E) | Lock | Below 1 Ω |
| 9 (L) - 7 (E) | Off | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Unlock | Below 1 Ω |
| 10 (UL) - 7 (E) | Off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (L) - 8 (E) | Lock | Below 1 Ω |
| 6 (L) - 8 (E) | Off | 10 kΩ or higher |
| 5 (UL) - 8 (E) | Unlock | Below 1 Ω |
| 5 (UL) - 8 (E) | Off | 10 kΩ or higher |
OK
NG
Disconnect the K6*1 and J6*2 door lock connectors.
*1: for LHD
*2: for RHD
Remove the G46 main body ECU (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K6-10 (UL) - G64-24 (UL3) | Always | Below 1 Ω |
| K6-9 (L) - G64-11 (L2) | Always | Below 1 Ω |
| K6-7 (E) - Body ground | Always | Below 1 Ω |
| K6-10 (UL) - Body ground | Always | 10 kΩ or higher |
| K6-9 (L) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J6-5 (UL) - G64-24 (UL3) | Always | Below 1 Ω |
| J6-6 (L) - G64-11 (L2) | Always | Below 1 Ω |
| J6-8 (E) - Body ground | Always | Below 1 Ω |
| J6-5 (UL) - Body ground | Always | 10 kΩ or higher |
| J6-6 (L) - Body ground | Always | 10 kΩ or higher |
OK
NG