When the light control rheostat knob is turned right, the combination meter and vehicle interior illumination will become brighter. When the light control rheostat knob is turned left, the combination meter and vehicle illumination will dim.
Using the GTS, read the Data List (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Tail Cancel SW* | Tail cancel switch/OFF or ON | OFF: Tail cancel switch off | - |
| ON: Tail cancel switch on | |||
| Rheostat value | Light control rheostat switch input/Min.: 0, Max.: 100 | Light control rheostat switch is fully turned right (0) → fully turned left (100) | Unit: % |
*: w/ TAIL Cancel Switch
Light brightness can be changed within specified range by manual operation.
OK
NG
Inspect the light control rheostat. (w/o TAIL Cancel Switch)
Remove the light control rheostat (See page Vehicle Interior>METER / GAUGE / DISPLAY>TRIP SWITCH>REMOVAL).
Measure the resistance according to the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (T) - 1 (E) | Always | 8 to 12 kΩ |
| 7 (RV) - 1 (E) | Light control rheostat fully turned right → fully turned left | Below 100 Ω → 8 to 12 kΩ |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8 (T) - 4 (E) | Always | 8 to 12 kΩ |
| 6 (RV) - 4 (E) | Light control rheostat fully turned right → fully turned left | Below 100 Ω → 8 to 12 kΩ |
Inspect the light control rheostat. (w/ TAIL Cancel Switch)
Remove the light control rheostat (See page Vehicle Interior>METER / GAUGE / DISPLAY>TRIP SWITCH>REMOVAL).
Measure the resistance according to the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (T) - 6 (TC) | TAIL cancel switch off → on | 1 MΩ or higher → Below 1 Ω |
| 5 (T) - 1 (E) | Always | 8 to 12 kΩ |
| 7 (RV) - 1 (E) | Light control rheostat fully turned right → fully turned left | Below 100 Ω → 8 to 12 kΩ |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8 (T) - 7 (TC) | TAIL cancel switch off → on | 1 MΩ or higher → Below 1 Ω |
| 8 (T) - 4 (E) | Always | 8 to 12 kΩ |
| 6 (RV) - 4 (E) | Light control rheostat fully turned right → fully turned left | Below 100 Ω → 8 to 12 kΩ |
OK
NG
Disconnect the G6 combination meter assembly connector.
Disconnect the G16 trip switch (light control rheostat) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G6-10 (TC) - G16-6 (TC)* | Always | Below 1 Ω |
| G6-6 (SW1) - G16-5 (T) | Always | Below 1 Ω |
| G6-7 (SW2) - G16-7 (RV) | Always | Below 1 Ω |
| G6-22 (SW3) - G16-1 (E) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G6-10 (TC) - G16-7 (TC)* | Always | Below 1 Ω |
| G6-6 (SW1) - G16-8 (T) | Always | Below 1 Ω |
| G6-7 (SW2) - G16-6 (RV) | Always | Below 1 Ω |
| G6-22 (SW3) - G16-4 (E) | Always | Below 1 Ω |
| G6-22 (SW3) - G16-4 (E) | Always | Below 1 Ω |
*: w/ TAIL Cancel Switch
OK
NG
Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.
Combination meter assembly operates normally.
OK
NG