Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE
RM27T0E _58 Vehicle Interior _053735 SUPPLEMENTAL RESTRAINT SYSTEMS _0261087 SPIRAL CABLE G

SUPPLEMENTAL RESTRAINT SYSTEMS  SPIRAL CABLE  INSPECTION  


PROCEDURE

Hide 84306 1.INSPECT SPIRAL CABLE SUB-ASSEMBLY (w/o Steering Heater)

a.

If any of the defects mentioned below are found, replace the spiral cable sub-assembly with a new one:

Scratches, cracks, dents or chips on the connector or the spiral cable sub-assembly.


b.
U169844E02
0.521,1.198 0.521,0.802 0.521,0.802 0.344,0.802 false 1.125,1.729 1.125,1.354 1.125,1.354 1.229,1.354 false 1.781,0.885 1.948,1.063 0.167,0.177 10 false z8 0.76,1.208 0.927,1.385 0.167,0.177 10 false z5 0.76,2.542 0.927,2.719 0.167,0.177 10 false z6 1.26,4.198 1.542,4.375 0.281,0.177 10 false G40 2.344,4.188 2.625,4.365 0.281,0.177 10 false G41 2.385,0.885 2.552,1.063 0.167,0.177 10 false z7 1.25,1.302 1.438,1.458 0.188,0.156 10 false *c 0.198,0.729 0.385,0.885 0.188,0.156 10 false *b 0.083,0 0.271,0.156 0.188,0.156 10 false *a

Check the spiral cable sub-assembly.

Text in Illustration
*a Component without harness connected
(Spiral Cable Sub-assembly)
*b Orange
*c Black

i.

Set the spiral cable sub-assembly to the center position (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>SPIRAL CABLE>INSTALLATION).


ii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise and measure the resistance according to the value(s) in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise and measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G41-1 - z5-2 Always Below 1 Ω
G41-2 - z5-1 Always Below 1 Ω
G41-3 - z6-1 Always Below 1 Ω
G41-4 - z6-2 Always Below 1 Ω
G40-6 - z8-10 Always 3 Ω or less
G40-5 - z8-9 Always 3 Ω or less
G40-4 - z8-8 Always 3 Ω or less
G40-3 - z8-7 Always 3 Ω or less
G40-2 - z8-6 Always 3 Ω or less
G40-2 - z7-4 Always 3 Ω or less
G40-1 - z7-3 Always 3 Ω or less
G40-12 - z8-5 Always 3 Ω or less
G40-11 - z8-4 Always 3 Ω or less
G40-10 - z8-3 Always 3 Ω or less
G40-9 - z8-2 Always 3 Ω or less
G40-8 - z8-1 Always 3 Ω or less
G40-8 - z7-2 Always 3 Ω or less
G40-7 - z7-1 Always 3 Ω or less



iii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times counterclockwise. Then while rotating the spiral cable sub-assembly 5 times clockwise, measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G41-1 - z5-2 Always Below 1 Ω
G41-2 - z5-1 Always Below 1 Ω
G41-3 - z6-1 Always Below 1 Ω
G41-4 - z6-2 Always Below 1 Ω
G40-6 - z8-10 Always 3 Ω or less
G40-5 - z8-9 Always 3 Ω or less
G40-4 - z8-8 Always 3 Ω or less
G40-3 - z8-7 Always 3 Ω or less
G40-2 - z8-6 Always 3 Ω or less
G40-2 - z7-4 Always 3 Ω or less
G40-1 - z7-3 Always 3 Ω or less
G40-12 - z8-5 Always 3 Ω or less
G40-11 - z8-4 Always 3 Ω or less
G40-10 - z8-3 Always 3 Ω or less
G40-9 - z8-2 Always 3 Ω or less
G40-8 - z8-1 Always 3 Ω or less
G40-8 - z7-2 Always 3 Ω or less
G40-7 - z7-1 Always 3 Ω or less


NOTICE:

As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.


If the result is not as specified, replace the spiral cable sub-assembly.



Hide 84306 2.INSPECT SPIRAL CABLE SUB-ASSEMBLY (w/ Steering Heater)

a.

If any of the defects mentioned below are found, replace the spiral cable sub-assembly with a new one:

Scratches, cracks, dents or chips on the connector or the spiral cable sub-assembly.


b.
U170729E02
0.49,1.073 0.49,0.625 0.49,0.625 0.354,0.625 false 0.76,1.063 0.76,0.615 0.76,0.615 0.896,0.615 false 1.417,0.781 1.729,0.938 0.313,0.156 10 false z8 1.885,0.781 2.198,0.938 0.313,0.156 10 false z7 0.125,0.844 0.438,1 0.313,0.156 10 false z5 0.948,1.521 1.26,1.677 0.313,0.156 10 false z6 2.396,2.479 2.708,2.635 0.313,0.156 10 false G40 2.844,2.49 3.156,2.646 0.313,0.156 10 false G41 0.385,2.25 0.667,2.438 0.281,0.188 10 false z14 0.698,3.781 1.073,3.948 0.375,0.167 10 false G151 0.052,0 0.26,0.167 0.208,0.167 10 false *a 0.208,0.531 0.417,0.698 0.208,0.167 10 false *b 0.927,0.531 1.135,0.698 0.208,0.167 10 false *c

Check the spiral cable sub-assembly.

Text in Illustration
*a Component without harness connected
(Spiral Cable Sub-assembly)
*b Orange
*c Black

i.

Set the spiral cable sub-assembly to the center position (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>SPIRAL CABLE>INSTALLATION).


ii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise and measure the resistance according to the value(s) in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise and measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G41-1 - z5-2 Always Below 1 Ω
G41-2 - z5-1 Always Below 1 Ω
G41-3 - z6-1 Always Below 1 Ω
G41-4 - z6-2 Always Below 1 Ω
G40-6 - z8-10 Always 3 Ω or less
G40-5 - z8-9 Always 3 Ω or less
G40-4 - z8-8 Always 3 Ω or less
G40-3 - z8-7 Always 3 Ω or less
G40-2 - z8-6 Always 3 Ω or less
G40-2 - z7-4 Always 3 Ω or less
G40-1 - z7-3 Always 3 Ω or less
G40-12 - z8-5 Always 3 Ω or less
G40-11 - z8-4 Always 3 Ω or less
G40-10 - z8-3 Always 3 Ω or less
G40-9 - z8-2 Always 3 Ω or less
G40-8 - z8-1 Always 3 Ω or less
G40-8 - z7-2 Always 3 Ω or less
G40-7 - z7-1 Always 3 Ω or less
z14-1 - G151-1 Always Below 0.1 Ω
z14-2 - G151-3 Always Below 0.1 Ω
z14-3 - G151-2 Always Below 0.1 Ω
z14-4 - G151-4 Always Below 0.1 Ω



iii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times counterclockwise. Then while rotating the spiral cable sub-assembly 5 times clockwise, measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G41-1 - z5-2 Always Below 1 Ω
G41-2 - z5-1 Always Below 1 Ω
G41-3 - z6-1 Always Below 1 Ω
G41-4 - z6-2 Always Below 1 Ω
G40-6 - z8-10 Always 3 Ω or less
G40-5 - z8-9 Always 3 Ω or less
G40-4 - z8-8 Always 3 Ω or less
G40-3 - z8-7 Always 3 Ω or less
G40-2 - z8-6 Always 3 Ω or less
G40-2 - z7-4 Always 3 Ω or less
G40-1 - z7-3 Always 3 Ω or less
G40-12 - z8-5 Always 3 Ω or less
G40-11 - z8-4 Always 3 Ω or less
G40-10 - z8-3 Always 3 Ω or less
G40-9 - z8-2 Always 3 Ω or less
G40-8 - z8-1 Always 3 Ω or less
G40-8 - z7-2 Always 3 Ω or less
G40-7 - z7-1 Always 3 Ω or less
z14-1 - G151-1 Always Below 0.1 Ω
z14-2 - G151-3 Always Below 0.1 Ω
z14-3 - G151-2 Always Below 0.1 Ω
z14-4 - G151-4 Always Below 0.1 Ω


NOTICE:

As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.


If the result is not as specified, replace the spiral cable sub-assembly.