The cooler thermistor (rear room temperature sensor) is installed in the rear panel. It detects the rear cabin temperature to control the air conditioning AUTO mode. The resistance of the cooler thermistor (rear room temperature sensor) changes in accordance with the rear cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (rear room temperature sensor) and reads voltage changes as the resistance of the cooler thermistor (rear room temperature sensor) changes.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1419/19 | Open or short in the cooler thermistor (rear room temperature sensor) circuit. | ·
Cooler thermistor (rear room temperature sensor) ·
Harness or connector ·
Air conditioning amplifier assembly |
Use the Data List to check if the rear room temperature sensor is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temp Sensor (Rear) | Cooler thermistor (rear room temperature sensor) /
Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual rear cabin temperature displayed | Open in the circuit: -6.5°C (- 20.3°F).
Short in the circuit: 57.25°C (135.05°F). |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
Remove the cooler thermistor (rear room temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR(for Rear Side)>REMOVAL).
| *a | Resistance | *b | Allowable Range |
| *c | Temperature | - | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (refer to the graph).
OK
NG
(See pageVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR(for Rear Side)>REMOVAL)
Disconnect the G24 amplifier connector.
Disconnect the Q19 sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Q19-1 - G24-17 (TR) | Always | Below 1 Ω |
| Q19-2 - G24-7 (SG-6) | Always | Below 1 Ω |
| Q19-1 - Body ground | Always | 10 kΩ or higher |
| Q19-2 - Body ground | Always | 10 kΩ or higher |
OK
NG