Hide 1.DISABLE AUTOAWAY/RETURN FUNCTION (for Power Tilt and Power Telescopic Steering Column)

a.

Disable the Autoaway/Return function by changing the customize parameter.

Click hereSteering>STEERING COLUMN>POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM>CUSTOMIZE PARAMETERS

NOTICE:

Record the current customize parameter setting (whether the Autoaway/Return function is enabled or disabled) in order to restore the current setting after finishing the operation.


HINT:

Performing the above operation causes the Autoaway/Return function to be disabled when the ignition switch is turned off.



b.

Turn the ignition switch to ON. Operate the tilt and telescopic switch to fully extend and lower the steering column.


c.

Turn the ignition switch off.


Hide 2. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 3.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:

Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.


NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 55471A 4.REMOVE INSTRUMENT CLUSTER FINISH PANEL ORNAMENT (for LHD)

Hide 55476C 5.REMOVE INSTRUMENT PANEL FINISH PLATE GARNISH (for RHD)

Hide 55480D 6.REMOVE LOWER INSTRUMENT PANEL FINISH PANEL ASSEMBLY

Hide 55404D 7.REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

a.

except 5L-E:

i.
B488146C01
0,0 0,0 false
V100155

Protective Tape


Place protective tape as shown in the illustration.


ii.

Detach the 4 claws.


iii.
B488147

Detach the 4 claws.


iv.

Detach the 2 clips and 2 guides.


v.

Disconnect the connector and remove the instrument cluster finish panel sub-assembly.



b.

for 5L-E:

i.
B449248C01
0,0 0,0 false
V100155

Protective Tape


Place protective tape as shown in the illustration.


ii.

Detach the 4 claws.


iii.
B486258

Detach the 4 claws.


iv.

Detach the 2 clips and 2 guides.


v.

Disconnect the connector and remove the instrument cluster finish panel sub-assembly.



Hide 83100 8.REMOVE COMBINATION METER ASSEMBLY

a.
E194816

Remove the 4 screws and combination meter assembly.


b.

Disconnect the 2 connectors.