Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR(for Rear) › from 2017.08
RM27T0E _56 Audio / Visual / Telematics _053722 PARK ASSIST / MONITORING _0260998 ULTRASONIC SENSOR(for Rear) A

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Rear)  INSTALLATION  


PROCEDURE

Hide 89348R 1.INSTALL REAR CORNER ULTRASONIC SENSOR RETAINER

HINT:
·

Perform this step only when necessary.

·

If a rear corner ultrasonic sensor retainer has been removed, replace it with a new one. Install the rear corner ultrasonic sensor with a new rear corner ultrasonic sensor retainer as a set to the rear bumper cover.

·

Use the same procedure to install the rear corner ultrasonic sensor retainer on the other side.



a.

Clean the rear bumper cover surface.

i.

Remove the remaining double-sided tape from the rear bumper cover.


ii.

Wipe off any tape adhesive residue with cleaner.



b.
B360651C02
0.76,0.271 1.073,0.427 0.313,0.156 10 false *a 2.521,0.438 2.833,0.594 0.313,0.156 10 false *a
*a 18 mm (0.709 in.)


for Corner Sensor:

i.

Cover the sensor installation hole with a 18 mm (0.709 in.) square piece of tape.



c.
B360651C02
0.76,0.271 1.073,0.427 0.313,0.156 10 false *a 2.521,0.438 2.833,0.594 0.313,0.156 10 false *a
*a 24 mm (0.945 in.)


for Back Sensor:

i.

Cover the sensor installation hole with a 24 mm (0.945 in.) square piece of tape.



d.
B488743C04
1.708,0.802 1.708,0.365 1.708,0.365 2.083,0.365 false 2.125,0.292 2.438,0.49 0.313,0.198 10 false *a
*a Mark-off Line
V100155

Primer


Using a brush or felt, apply primer or equivalent to the rear corner ultrasonic sensor retainer installation area.

NOTICE:
·

Use a clean brush or felt.

·

Do not touch the rear bumper cover until the primer has dried.




e.

Using a heat light, heat the rear bumper cover.

Standard:
Item Temperature
Rear Bumper Cover 40 to 60°C (104 to 140°F)


CAUTION:
E306500C01
2.365,2 2.698,2 false 0.5,2.333 0.5,2.667 true 0.427,2.708 0.74,2.865 0.313,0.156 10 false *a 2.76,1.927 3.073,2.083 0.313,0.156 10 false *b
*a Heated Part
*b Heat Light


·

Do not touch the heat light and heated parts.

·

Touching the heat light may result in burns.

·

Touching heated parts for a long time may result in burns.



NOTICE:

Do not heat the rear bumper cover excessively.



f.

Peel off the release paper from a new rear corner ultrasonic sensor retainer.


g.

Align the rear corner ultrasonic sensor retainer with the alignment line and set it on the rear bumper cover as shown in the illustration.

NOTICE:

The double-sided tape of a rear corner ultrasonic sensor retainer will deteriorate if it is detached. Make sure to replace the rear corner ultrasonic sensor retainer with a new one when reattachment is necessary.


HINT:
·

Align the connector side with the protrusion of the mark and install it.

·

Press the rear corner ultrasonic sensor retainer with a force of 30 N (3.0 kgf) for 3 seconds and install the rear corner ultrasonic sensor retainer firmly so that there is no clearance between the rear corner ultrasonic sensor retainer and rear bumper cover.



B488744C01
2.344,0.948 2.708,1.125 false 1.302,0.417 1.771,0.333 false 1.177,1.229 1.521,1.031 false 2.76,1.073 3.073,1.229 0.313,0.156 10 false *c 1.833,0.25 2.146,0.406 0.313,0.156 10 false *b 1.021,1.208 1.333,1.365 0.313,0.156 10 false *a
*a Alignment Line *b Connector Side
*c Protrusion of the mark - -



Hide 89342 2.INSTALL REAR CORNER ULTRASONIC SENSOR

NOTICE:

When reusing the ultrasonic sensor, make sure that each ultrasonic sensor is returned to its original position.


HINT:

Use the same procedure to install the rear corner ultrasonic sensor on the other side.


a.

Attach the 2 claws to install the rear corner ultrasonic sensor.


b.

Connect the connector.


Hide 89348S 3.INSTALL REAR CENTER ULTRASONIC SENSOR RETAINER

HINT:

Use the same procedure described for the rear corner ultrasonic sensor retainer.


Hide 89342A 4.INSTALL REAR CENTER ULTRASONIC SENSOR

HINT:

Use the same procedure described for the rear corner ultrasonic sensor.


Hide 89348D 5.INSTALL ULTRASONIC SENSOR CLIP

HINT:

Use the same procedure to install the ultrasonic sensor clip on the other side.


a.

Attach the claw to install the ultrasonic sensor clip.