This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when turn the ignition switch to ON, the indicator will not operate.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the combination meter assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G304-20 - Body ground | Always | Always |
| G6-21 (E2) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G6-28 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| G6-26 (B) - Body ground | Always | 11 to 14 V |
| *A | except 5L |
| *B | for 5L |
| *a | Front view of wire harness connector
(to Combination Meter Assembly |
OK
NG